13.1
operator cleaning
In order to ensure long-term operation of the robot, the operator shall be
cleaned regularly every 960 hours or 3 months (whichever is shorter). The
process is as follows:
Adjust the robot to the calibration state.
To prevent danger, turn off the power, hydraulic and pneumatic sources
connected to the robot.
Clean the operator with a vacuum cleaner or wipe with a cloth
After ensuring all safety conditions are met, carry out follow-up work of
the operator.
Warning
It is forbidden to use water jet on the operator, especially the connector, seal or
cable inlet and outlet.
Do not use compressed air to clean the operator.
Do not remove any operator protection.
Do not use solvent to clean the operator.
13.2
cable maintenance
To ensure the long-term operation of the robot, check the cable of the operator
every 1920 hours or 6 months (whichever is shorter), and the cable layout is
shown in Fig. 13-1: