AIR10-1420A Operation Manual
Project maintenance process
39
Fig. 13-2 Cables inside the base
Elbow internal cable maintenance process
Remove the elbow cable fixing plate, as shown in Fig. 13-3.
Pull out the cable and check whether the connection between the cable
and the fixed plate is reliable.
Check whether there is abrasion or damage at the fixing place of cable
and bracket.
Check the internal cable for wear or damage.
In case of any crack, wear or damage, the company shall be contacted in
time for replacement
Check whether the internal cable surface grease disappears.
If the lubricating grease on the cable surface disappears, it shall be
supplemented in time
Install the cable inside the elbow.
Install the cable retainer plate.
Fig. 13-3 cable inside elbow
Cable Fixed plate screw
Electrical installation board
screw
Cable
Bracket
M4X8