EN 6
USE
Controls
Switching the light on and off
1. Use slider A to turn the lights on or off.
For use as a motorless hood connected to an central extraction
system.
Opening and closing the electric valve
1. Move the slider to position 2.
The electric valve opens. The control light will illuminate.
2. Move the slider to position 0/1.
The electric valve closes.
For use with a CMV system, were the motorspeed is controlled by
the hood.
Opening or closing the electric valve and switching the external motor
fan on or off.
• At position 0/1:
▷
the external motor is working on speed one.
▷
the valve is closed with open hole (small valve in ‘open’ position)
for basic ventilation of the central mechanical ventilation system.
▷
The control light is off.
1. Move the slider to position 2 or 3.
The cooker hood switches the central extraction system at the
corresponding speed. The control light will illuminate. The electric
valve will open.
2. Move the slider to position 0/1.
The control light is off. The electric valve will close. The central
extraction system is working at speed one.
Note!
When using the hood to control the central extraction system
speed, the small valve inside the electric valve needs to be put in the
‘open’ position (see ‘Installation’).