23
TROUBLESHOOTING
Problem:
Cause or remedy
Appliance is connected
to the power mains but
it does not work.
• Make sure there is voltage in the power outlet and
that the appliance is switched on.
Cooling system
operates continuously
for a long period of
time:
• Too high ambient temperature.
• Door opened too frequently or too long.
• Door not closed correctly (possible impurities on
the seal, misaligned door, damaged seal etc.).
• Too much fresh food inserted at once.
• Insufficient compressor and condenser unit
cooling. Check for sufficient air circulation behind
the appliance and clean the condenser unit.
Temperature display
and/or LED lighting
flashing.
• The door has been opened for too long or too
frequently. Close the door properly. After two
hours, open the door again. If the set temperature
and/or LED lighting are still flashing, call the
service centre.
• The door does not seal properly (the seal is dirty,
the door is misaligned or the seal is damaged,
etc.).
• Too much fresh food has been put in at the same
time.
Build-up of ice or frost
in the freezer interior
may be a result of the
following:
• The freezer compartment has not been defrosted
periodically. Defrost the freezer compartment to
remove the ice.
• Door not properly closed.
• The door does not seal properly (the seal is dirty,
the door is misaligned or the seal is damaged,
etc.).
Door is difficult to open:
• If you are trying to open the freezer door after
just having closed it, this could be difficult to do.
As you open the door, some cool air escapes from
the appliance and it is replaced by warm air from
the environment. When this air is cooled, negative
pressure is generated which results in problems as
you try to open the door. After a few minutes, the
condition is normalized and the door can be easily
opened again.
726355
Summary of Contents for PVS24088L
Page 1: ...Gebruiksaanwijzing Inbouwvriezer PVS24088L PVS24102N PVS24140N ...
Page 28: ...nl 05 19 FREEZER BI540 F2 ESS PEL ...
Page 29: ...Bedienungsanleitung Einbau Gefrierschrank PVS24088L PVS24102N PVS24140N ...
Page 56: ...FREEZER BI540 F2 ESS PEL de 05 19 ...
Page 57: ...Mode d emploi Congélateur armoire encastrable PVS24088L PVS24102N PVS24140N ...
Page 84: ...fr 05 19 FREEZER BI540 F2 ESS PEL ...
Page 85: ...Instructions for use Built in freezer PVS24088L PVS24102N PVS24140N ...
Page 109: ...25 726355 ...
Page 110: ...26 726355 ...
Page 111: ......