background image

EXTERIOR FINISH

The exterior frame and sash are protected by aluminum cladding with our EnduraClad® or 
EnduraClad Plus baked-on factory finish that needs no painting. Clean this surface with mild 
soap and water. Stubborn stains and deposits may be removed with mineral spirits. DO NOT 
use abrasives. DO NOT scrape or use tools that might damage the surface.

Use of inappropriate finishes, solvents, brickwash or cleaning chemicals will cause adverse 
reactions with window and door materials and voids the Limited Warranty.

CARE AND MAINTENANCE

Care and maintenance information is available in the Pella Owner’s Manual. You can 
obtain an owner’s manual by contacting your local Pella retailer. This information is also 
available on 

www.pella.com.

IMPORTANT NOTICE

Because all construction must anticipate some water infiltration, it is important that the wall 
system be designed and constructed to properly manage moisture. Pella Corporation is not 
responsible for claims or damages caused by anticipated and unanticipated water infiltration; 
deficiencies in building design, construction and maintenance; failure to install Pella products 
in accordance with Pella’s installation instructions; or the use of Pella products in wall 
systems which do not allow for proper management of moisture within the wall systems. The 
determination of the suitability of all building components, including the use of Pella products, 
as well as the design and installation of allow for proper management of moisture within the 
wall systems. The determination of the suitability of all building components, including the 
use of Pella products, as well as the design and installation of flashing and sealing systems are 
the responsibility of the Buyer or User, the architect, contractor, installer, or other construction 
professional and are not the responsibility of Pella.

Pella products should not be used in barrier wall systems which do not allow for proper 
management of moisture within the wall systems, such as barrier Exterior Insulation and Finish 
Systems, (EIFS) (also known as synthetic stucco) or other non-water managed systems. Except 
in the states of California, New Mexico, Arizona, Nevada, Utah, and Colorado, Pella makes no 
warranty of any kind on and assumes no responsibility for Pella windows and doors installed in 
barrier wall systems. In the states listed above, the installation of Pella Products in barrier wall or 
similar systems must be in accordance with Pella’s installation instructions.

Product modifications that are not approved by Pella Corporation will void the Limited Warranty.

$JSDMF)FBE

'VMM$JSDMF

5SBQF[PJE

0DUBHPO

"SDI)FBE

3FDUBOHMF

2VBSUFS$JSDMF

)BMG$JSDMF

0WBM

%PH)PVTF

3JHIU5SJBOHMF

Additional cutting patterns

Summary of Contents for 801U0103

Page 1: ...aintenance instructions may void your Pella product warranty See Limited Warranty for complete details at http warranty pella com INSTALLATION INSTRUCTION STANDARD PERFORMANCE UPGRADE AND HURRICANESHI...

Page 2: ...framing members REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT A Make sure the bottom of the opening is level Note It is critical the bottom is level for the window to be installed correctl...

Page 3: ...s If installation ns are used place the clip so that the lip is facing up and against the installation n at the locations shown in the placement diagram If installation ns are not used the clip lip fa...

Page 4: ...or sealant details Center window between the sides of the opening to allow clearance for shimming and insert one 6 x 1 1 2 or longer screw into one hole in each of the top corner clips This will hold...

Page 5: ...window Press the tape down rmly while folding down the excess tape at the top and bottom of the window Note DO NOT tape or seal the bottom nailing n C Apply top ashing tape Cut a piece of ashing tape...

Page 6: ...to circle top windows Several pieces of ashing tape will be needed to cover the top n Start taping from the sides of the window working toward the peak To determine the length of cuts hold the tape a...

Page 7: ...ctly follow the foam manufacturer s recommendations for application Use of high pressure foams or improper application of the foam may cause the window frame to bow and hinder operation 6 INTERIOR SEA...

Page 8: ...nstructions for these and any other applications 7 45 4 MFBSBODF BDLFS 3PE BOE 4FBMBOU UZQJDBM OTVMBUJOH PBN 1FSJNFUFS 4FBMBOU NVTU FYUFOE UP SPPNTJEF PG DDFTTPSZ SPPWF DDFTTPSZ SPPWF 800 4 8 5 53 OTV...

Page 9: ...eel wool BE CAREFUL NOT TO SCRATCH THE GLASS Remove sanding dust Note To maintain proper product performance do not paint nish or remove the weather stripping mohair dust pads gaskets or vinyl parts A...

Page 10: ...per management of moisture within the wall systems The determination of the suitability of all building components including the use of Pella products as well as the design and installation of allow f...

Reviews: