background image

ADDITIONAL CUTTING PATTERNS

$JSDMF)FBE

'VMM$JSDMF

5SBQF[PJE

0DUBHPO

"SDI)FBE

3FDUBOHMF

2VBSUFS$JSDMF

)BMG$JSDMF

0WBM

%PH)PVTF

3JHIU5SJBOHMF

Because all construction must anticipate some water infiltration, it is important that the wall system be 
designed and constructed to properly manage moisture. Pella Corporation is not responsible for claims 
or damages caused by anticipated and unanticipated water infiltration; deficiencies in building design, 
construction and maintenance; failure to install Pella

®

 products in accordance with Pella installation 

instructions; or the use of Pella products in wall systems which do not allow for proper management 
of moisture within the wall systems. The determination of the suitability of all building components, 
including the use of Pella products, as well as the design and installation of flashing and sealing systems 
are the responsibility of the Buyer or User, the architect, contractor, installer, or other construction 
professional and are not the responsibility of Pella.

Pella products should not be used in barrier wall systems which do not allow for proper management of 
moisture within the wall systems, such as barrier Exterior Insulation and Finish Systems (EIFS) 

ALSOKNOWNASSYNTHETICSTUCCO OROTHERNONWATERMANAGEDSYSTEMS%XCEPTINTHESTATESOF
#ALIFORNIA.EW-EXICO!RIZONA.EVADA5TAHAND#OLORADO

Pella makes no warranty of any kind 

and assumes no responsibility for Pella windows and doors installed in barrier wall systems. In 
the states listed above, the installation of Pella products in barrier wall or similar systems must be 
in accordance with Pella installation instructions.

Product modifications that are not approved by Pella Corporation will void the Limited Warranty.

IMPORTANT NOTICE

Summary of Contents for 80GZ0102

Page 1: ...ting an experienced architect contractor or structural engineer prior to installation of Pella products The individual building owner architect contractor installer and or consumer responsible for the...

Page 2: ...E APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT B Verify the window will t the opening Measure all four sides of the opening to MAKE SURE IT IS LARGER THAN THE WINDOW in both width and height On larger op...

Page 3: ...G from each side Spacers are also required at points where windows are joined in multiple window applications Add shims as necessary to ensure the spacers are level Once level attach spacers and shims...

Page 4: ...each installation screw hole Adjust the shims as required to plumb and square the window in the opening Note DO NOT over shim C Check the interior reveal Make sure the measurement from the interior fa...

Page 5: ...dow Position the tape so it laps ONTO THE FRAME CLADDING COVERS THE lN AND LAPS ONTO THE WATER RESISTIVE BARRIER 4HE TAPE SHOULD EXTEND ABOVE THE TOP OF THE WINDOW AND BELOW THE BOTTOM OF THE WINDOW 0...

Page 6: ...al cuts in the water resistive barrier Apply the tape covering the entire diagonal cut in the resistive water barrier at both upper corners of the window Note Be sure to overlap the top corners 4E 5 S...

Page 7: ...PG DDFTTPSZ SPPWF DDFTTPSZ SPPWF OTVMBUJOH GPBN JO 7 45 4 JO MFBSBODF BDLFS 3PE BOE 4FBMBOU UZQJDBM OTVMBUJOH GPBN 1FSJNFUFS 4FBMBOU NVTU FYUFOE UP SPPNTJEF PG DDFTTPSZ SPPWF DDFTTPSZ SPPWF 7 INTERIO...

Page 8: ...e the sash to stick it is optional to paint stain or nish the HORIZONTAL SASH EDGES s N PATIO DOORS IT IS OPTIONAL TO PAINT STAIN OR lNISH THE VERTICAL AND HORIZONTAL PANEL EDGES Note To maintain prop...

Page 9: ...lla products as well as the design and installation of ashing and sealing systems are the responsibility of the Buyer or User the architect contractor installer or other construction professional and...

Reviews: