28
User’s manual HANDHELD TOUCH RADIO
User’s manual HANDHELD TOUCH RADIO
Pag.36
Pag.37
Vers. 01 of:07.04.14
Vers. 01 of:07.04.14
FLAME
DESCRIPTION
RDS SYSTEM ADJUSTMENT
REQUEST
(only if the RDS system is provi-
ded)
It shows that the testing procedure and initial parameter calibration have not been comple-
ted or have been performed incorrectly. This indication, however, does not block the stove.
SERVICE REQUEST
The threshold value of set work hours has been reached. The symbol displayed remains
active throughout the work phase. Non-routine maintenance is required on the stove.
AIR FLOW METER FAILU-
RE
(only if the RDS system is provi-
ded)
It shows a failure of the air flow meter and the stove switches to minimum capacity disabling
the RDS system.
Warning Pop-Up
PHASE
DESCRIPTION
START/RESTART WAIT
Switch-on is requested but with the stove in cooling phase; once this condition is met, it
restarts automatically.
SWITCH ON RESTART
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
HOT SMOKE
The maximum fume temperature threshold has been reached. To facilitate cooling, the
stove brings the capacity to a minimum with ventilation at power level 5, leading to a decre-
ase
in fume temperature.
OFF
The stove is off
WAIT FOR PELLETS
OUT OF
When the switch-on request from ECO-STOP mode coincides with an
automatic switch-off condition (from the TIMER), the stove turns on ensuring total cleaning
of the brazier before switching to FINAL CLEANING.
INFEED SCREW
OVERFLOW
CONDITION: when the pellet setting (set p5) is near the continuous load condition.
SOLUTION: Set the value back to 0.
GENERIC ALARM
The stove is in alarm state; refer to the throubleshooting chapter.
ANOMALY (general)
The stove has detected an anomaly; refer to the throubleshooting chapter.
AUTOMATIC CLEANING
SYSTEM
ACTIVE
For models with semiautomatic cleaning it indicates the state of the same.
REASON
SOLUTION
• The door and the ash box are not closed correctly
• Make sure they are properly closed.
• Poor combustion in grate.
• Switch off the stove, clean the brazier and check the cleanliness of the
support bench, clean the tube bundle by activating the turbolators. and
adjust the combustion through Pellet/Air settings.
• Presence of foreign body in air intake tube.
• Check for any foreign body and remove it
• The air flow meter may be dirty.
• Clean the flow meter with the stove in "Switched off" state
• Contact the Support Service
SIGNALLING
RUN
BRAZIER CLEANING
(only if the RDS system is
provided)
The appearance of the message “ADJUST THE RDS SYSTEM” indicates that the initial parameter testing procedure and
calibration has been unsuccessfully. This indication does not block the stove.
Alarms (table with reference codes)
TRIAL
TITLE
REASON
SOLUTION
AL 01 BLACK OUT
- No voltage during work phase
- Press the switch off key and switch on
boiler switch-on.
- If the problem persists, contact the Support
Service
AL 02 FUME PROBE
- The fume probe is malfunctioning
- Contact the Support Service
- The fume probe is disconnected from the electro-
nic board
- Contact the Support Service
AL 03 FUME OVERTEMP.
- Combustion in the brazier is not optimal due to
clogging or obstructions of internal stove ducts
- Switch off the stove, clean the brazier and the
tube bundle and adjust the combustion setting
the Pellet/Air values
- The tangential fan (if provided) is
malfunctioning or damaged
- Contact the Support Service
- If the problem persists, contact the Support
Service
AL 04 FUME EXHAUST DAMAGED
- Fume exhaust encoder is not working or is
connected incorrectly
- Contact the Support Service
- No power to fume exhaust system
- Contact the Support Service
- The fume exhaust system is blocked
- Contact the Support Service
AL 05 NO SWITCH-ON
- The pellet tank is empty
- Check for the presence of pellets in the contai-
ner. Top up, if necessary.
- Pellet calibration and suction during switch on
phase is incorrect.
- Contact the Support Service
- The igntition coil is faulty or positioned
- Contact the Support Service
AL 06 PELLETS FINISHED
- The pellet tank is empty.
- Check for the presence of pellets in the contai-
ner. Top up, if necessary.
- The gear motor is not loading pellets
- Empty the tank to see if there are any objects
inside that may prevent the proper operation of
the auger.
- Not enough pellets loaded
- Regulate pellets setting from “SET AIR/PEL-
LETS”
- If the problem persists, contact the Support
Service Support
AL 07 RESET THERMAL BREAKER / PELLET
DOOR OR GATE OPEN
- The manual reset thermostat has tripped
connected to the hopper (RESET THERMAL
BREAKER /
Pellet door or gate is open
- Reset the thermostat by pressing the button on
the back of the stove or close the doors.
- Combustion in the grate is not optimal due
to the fact that the grate is clogged or the inner
stove ducts are clogged. (RESET THERMAL
BREAKER)
- Switch off the stove, clean the brazier and the
tube bundle and adjust the combustion setting
the Pellet/Air values
- Contact the Support Service
AL 08 DEPRESSURIZATION
- The flue is blocked.
Check the flue is free and clean
- The vacuum meter is faulty.
- Contact the Support Service
AL 12 FUME EXHAUST SYSTEM
FAILURE
- T he fume exhaust system has a loss of perfor-
mance due to fan obstruction or voltage drop.
- Contact the Support Service
AL 14 SCREW PHASE
- No cable connection to power the gear motor
of the auger
- Contact the Support Service
AL 15 AUGER TRIAC
- An internal part of the electronic board that
controls the pellet infeed screw is faulty.
- Contact the Support Service
- Possible voltage drops or incorrect input voltage
stove inlet
- Check the mains voltage.
AL 17 NO FLOW
(only if the RDS system is provided)
- The flow meter does not measure inlet air flow
- Check if the ash pan and door are
closed correctly and check if the air inlet pipe is
obstructed.
- If the problem persists, contact the Support
Service
AL 19 CLEANER FAILURE
(for models equipped with cleaner)
- The cleaner did not complete the movement and
is not in the correct position
- Reset the alarm and wait for the stove
to switch to SHUTDOWN mode. Cut off and
power again, the system reactivates the cleaner
trying to search the correct position again.
-- If the problem persists, contact the Support
Service
Excessive
Load
Adjust RDS
system
modulate
6.9.1 Alarms