PV20a / PV30a pellet burner
page
21/ 41
DK9902A1 www.pelltech.eu
OK
More than 3 sec
Resetting error status and turning burner ON
OK
More than 3 sec in
INFO
menu’s
COUNTER
submenu
Resetting pellets counter
OK
More than 3 sec in NO POWER
status
Switching burner and battery OFF
ESC
Less than 3 seconds
Moving back in menu. Cancelling setting
(when blinks)
OK + ESC
More than 3 seconds
Burner’s reset
Starting and stopping
4.2
Starting burner is described more precisely in ch 2.5.
To turn on the burner:
Turn on the boiler main switch. If burner displays STOPPED, in main menu set BURNER from
OFF to ON or
Press OK button down for 5 seconds.
To stop the burner:
Turn boiler’s thermostat to lowest temperature
In main menu set BURNER from ON to OFF.
In all cases the burner stops working when all pellets in burning chamber are burnt and turns safely to
STOPPED status.
Warning!
Never turn off working burner from boilers main switch. Use the boilers thermostate for that.
In order to complete burning procedure safely let the burner to burn all fuel in burning chamber. Never
leave burner unattended when you had to stop boilers work by turning boiler off from mains switch in
any reason.
Refilling fuel
4.3
The fuel container has to be refilled before it runs empty. Fuel can be added at any time during the
operation. To add fuel, simply pour a new bag of pellets into your fuel container.
If the container runs empty before new fuel is added, pour more fuel into container and restart the
burner from main menu. Starting will take more time because external auger has to be loaded as in
initial start up. Turn burner OFF and then ON. Vice verse NO PELLETS is displayed due to exceeded
loading time.
Log description
4.4
Log screen STATUS menu displays last and actual events (burner statuses) and their duration. Burner
changes its statuses based on received input signals from sensors and parameters set by user.
The duration of all actions is in form mm:ss (“m” in the middle) or hh:mm (“h” in the middle).
For
example: IGNITING 01m25 means the burner ignition state lasted 1 minute and 25 second.
Lower row of the log shows current state. To reach the lower row, press the “down” (↓) button,
until you reach the lower row with current state. The duration of current state updates every second or
every minute. Changed data blinks
.
Burner statuses are described in Table 8.
Table 8 Burner statuses
Status
Description
STOPPED
Burner is turned off.