2.1
Safety instructions for installation, use and service
The owner / user shall read and understand this manual before installation and operation of the burner.
For proper function and to avoid accidents and damage, these instructions must be followed. Wrong
handling and incorrect settings can result in injury, damage and / or malfunction of the equipment.
Following instructions apply:
Do not start the burner before it is connected to the boiler and the boiler is connected to the chimney.
To guarantee the efficiency of the appliance and ensure that it functions correctly, it is vital that
qualified personnel performs annual maintenance.
When the burner is connected to the main power supply the burner casing must always be mounted
Always make sure that the burner is unplugged from the main power supply before performing any
cleaning or maintenance.
Keep children away and do not touch the equipment during operation.
Make sure that no flammable or liquid materials are stored in the boiler room or vicinity of the boiler.
It is recommended to wear a respirator while handling pellets.
The boiler room where the burner is installed must fulfil all rules and recommendations in accordance
with local codes and regulations.
All electrical installation, plumbing, chimney sweeping and service work shall be done by certified and
qualified personnel in accordance with local codes and regulations.
2.2
Safety instructions regarding maintenance and cleaning
Touching live components can result in life threatening injuries. After switching the control unit off, there
are still live components inside the control unit until enclosure:
Switch OFF the power supply, e.g. at mains, and check the system is disconnected.
Hot surfaces and fluids can lead to burns:
Before maintenance and cleaning work, switch OFF the system and let it cool down.
Never touch hot surfaces on the boiler, burner, flue system or pipework.
Wear suitable personal protective equipment.
Hot surfaces and fire from aperatures can result in severe burns:
Doors, covers and aperatures fastened shut with screws must not be opened during heating
operation.
Allow hot components to cool down before removing.
When operating the ash container, there is a risk of fire and burns:
Wear suitable personal protective equipments.