HEATING SPECIFICATIONS
-
Approx. Heating capacity (Sq Feet) ¹
= 800 – 2,000 sq ft
- Approx. Fuel burn rate per hour ¹¹
= 1.5 – 5.5 lbs per hour
- Hopper Capacity
= 55-60 pounds
- Approx. Burn time on lowest setting *`
= 37 hours
DIMENSIONS
PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE
.
ELECTRICAL SPECIFICATIONS
Electrical Rating
= 115 Volts 60 HZ 2.0 Amps
Watts (operational)
= 175 (approximately)
Watts (optional igniter)
= 475 (approximately)
A voltage surge protector or ground fault outlet is required for this unit. The warranty on the circuit
board will be voided if surge protection is not installed before operating this unit.
ELECTRICAL BACK UP CONSIDERATIONS
If power outages are a concern, you may wish to purchase a gas powered generator, solar or battery
back-up system. Ensure that it is a ―Positive‖ sign wave and a minimum 1000 watts continual.
EPA COMPLIANCE
This heater is exempt from EPA Phase II requirements, but has been tested for emissions using EPA test
methods by Warnock Hersey , US. As listed by EPA under the name Hearth & Home Technologies with an
efficiency of over 77% and emissions of under 1 gram/hour. The unit is also certified with the State of
Oregon D.E.Q. and the State of Colorado Air Quality Control Commissions.
¹ Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and
the outside temperature. Fuel size, quality, density and moisture level will also have an effect.
¹¹ Pellet size may affect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as
much as 20%. Use PFI listed fuel for best results.
PelPro Series FPP4STBD
Freestanding Pelpro Multi-Fuel Step Top
Model : FPP
S
S
PECIFICATIONS
PECIFICATIONS
PelPro Appliances www.pelprostoves.com 8