PelPro Pellet Stove • 7104-171A • 4/20/18
pelprostoves.com
28
Troubleshooting
Alarm
(LED Flashing RED)
Possible Cause
Corrective Action
1 Flash: Empty
Hopper
No fuel is delivered to the fire pot to sustain flame
Hopper empty (most likely)
Auger Jam (next likely)
No vacuum
Hopper lid open
Flame is evident but the exhaust probe is not able
to recognize the hot exhaust temperature
Exhaust probe not attached to outlet
Exhaust path is dirty
Fill the hopper, inspect the feed tube for jams,
inspect the venting and firebox for obstructions
and clean if necessary, inspect the exhaust
blower to make sure it runs, or close the
hopper lid.
Inspect and clean the exhaust outlet, firebox,
fire pot, and behind the baffles. Inspect the
exhaust probe to see if it is securely attached
to the side of the exhaust outlet.
2 Flashes: Exhaust
Probe Fail
The exhaust probe
senses a temperature
of less than negative
20 degrees Celsius or
above 300 degrees
Celsius.
The exhaust temperature is above or below the
acceptable range.
Exhaust Probe Failure
Not plugged in
Failed component
Plug the probe into the board
Replace the component
3 Flashes: Ambient
Probe Alarm
The ambient probe
senses a temperature
of less than negative
20 degrees Celsius
or above 70 degrees
Celsius.
The ambient temperature is above or below the
acceptable range.
Ambient Probe Failure
Not plugged in
Failed component
Plug the probe into the board
Replace the component
4 Flashes: Missed
Ignition
During the ignition
sequence the load
does not ignite. The
Stove will automatically
retry once from the first
failed attempt.
Fuel
No fuel
Hopper Empty
Feed Jam
Feed doesn’t turn
Feed motor disconnected or failed
Fire pot
Fire pot Dirty so fuel is not near ignition hole
in the fire pot
Igniter
No power
Debris in the end of the igniter chamber
Fill the hopper
Inspect and clear jam in the feed tube
Inspect the feed motor circuit (hopper lid must
be closed, vacuum switch must be closed (ie
exhaust blower on), and feed motor must be
plugged in.
Clean the fire pot
Check leads and if the igniter works.
Clean the end of the igniter chamber from
inside the firebox (removal of the fire pot
required for this step).
8 Flashes: Exhaust
Over Temperature
The exhaust tempera-
ture has exceeded the
allowable temperature.
Fuel
Feed Motor Locked On
Non-approved fuel used
Convection blower
Dirty
Failed
Installation
Installation configuration is tight allowing for
limited air circulation around the Stove.
Review the feed motor and feed rates. Normal
feed motor operation is on between 1* and 4*
seconds out of every 7 seconds. (*depending
on model and burn rate setting)
If the feed motor does not turn off, replace the
control board.
Review the fuel being used.
Clean
Replace
Review the installation and move if necessary.
Following correction of any alarm, turn the dial control to the OFF position, wait 10 seconds and
turn back to desired setting OR unplug the Stove, wait 10 seconds then restore power.
Troubleshooting
100 of 112
Summary of Contents for PP130-B
Page 15: ...1445 North Hwy Colville WA 99114 800 234 2508 Low 15 of 112 ...
Page 28: ...28 of 112 ...
Page 29: ...29 of 112 ...
Page 33: ...33 of 112 ...
Page 35: ...35 of 112 ...
Page 36: ...36 of 112 ...
Page 37: ...37 of 112 ...
Page 38: ...38 of 112 ...
Page 39: ...39 of 112 ...
Page 41: ...41 of 112 ...
Page 42: ...42 of 112 ...
Page 43: ...43 of 112 ...
Page 44: ...44 of 112 ...
Page 47: ...1 19 2018 47 of 112 ...
Page 50: ...1 19 2018 50 of 112 ...
Page 51: ...51 of 112 ...
Page 52: ...52 of 112 ...
Page 53: ...53 of 112 ...
Page 55: ...55 of 112 ...