1445 North Hwy, Colville, WA 99114; 800-234-2508
Test Instruction Recommendations: PP130-B
Created on/by
: 03/20/18; C. Winslow Howe
–
HHT Design Engineer
Purpose
: To create repeatability in test protocol of the stove.
Hopper Fuel:
Hopper of the unit should be loaded up with a full 3 bags of fuel (Each bag weighing 40lb)
Test Settings:
Unit should be set up using a 6in flue and 115VAC power source,
High:
Dial should be set to 10 and the trim pot should be set to +4. When the unit is set and running at
this setting the light above the dial control will Flash 5 times with a pause between each sequence
Medium:
Dial should be set to 3 and the trim pot should be set to +3 When the unit is set and running at
this setting the light above the dial control will flash 2 times with a pause between each sequence.
Low:
Dial should be set to 1 and the trim pot should be set to 0. When the unit is set and running at this
setting the light above the dial control will flash once with a pause between each flash.