OMNI-Test Laboratories, Inc.
Pellet Heater Preburn Data - ASTM E2779
PB Length: 60 min
Recording Interval:
5 min
289
71
0
9
0
Elapsed
Time (min)
Scale
Reading
Weight
Change
Stack (F)
Ambient
(F)
Draft
("H2O)
CO2 (%)
CO (%)
0
26.6
-
231
69
-0.04
8.48
0.00
1
5
26.1
-0.5
265
69
-0.04
9.36
0.00
2
10
25.6
-0.5
285
70
-0.05
10.59
0.00
3
15
25.1
-0.5
293
70
-0.05
11.12
0.01
4
20
24.6
-0.5
298
70
-0.05
10.38
0.00
5
25
24.1
-0.5
302
71
-0.05
9.31
0.00
6
30
23.7
-0.4
294
72
-0.05
10.49
0.00
7
35
23.2
-0.5
294
70
-0.05
11.19
0.01
8
40
22.7
-0.5
297
71
-0.05
0.96
0.09
9
45
22.2
-0.5
302
71
-0.05
11.30
0.02
10
50
21.7
-0.5
299
71
-0.05
9.35
0.00
11
55
21.2
-0.5
301
72
-0.05
10.26
0.00
12
60
20.8
-0.4
293
71
-0.05
9.00
0.00
13
14
15
Averages:
Hearth & Home
PP130B
2266
0135PS041E
3/26/2018
Manufacturer:
Model:
Tracking No.:
Project No.:
Test Date:
Control No. P-SFDK-0003, Effective Date 5/6/16
File - 135PS041E PP130 Run 1, Tab - Pre burn
18 of 112
Summary of Contents for PP130-B
Page 15: ...1445 North Hwy Colville WA 99114 800 234 2508 Low 15 of 112 ...
Page 28: ...28 of 112 ...
Page 29: ...29 of 112 ...
Page 33: ...33 of 112 ...
Page 35: ...35 of 112 ...
Page 36: ...36 of 112 ...
Page 37: ...37 of 112 ...
Page 38: ...38 of 112 ...
Page 39: ...39 of 112 ...
Page 41: ...41 of 112 ...
Page 42: ...42 of 112 ...
Page 43: ...43 of 112 ...
Page 44: ...44 of 112 ...
Page 47: ...1 19 2018 47 of 112 ...
Page 50: ...1 19 2018 50 of 112 ...
Page 51: ...51 of 112 ...
Page 52: ...52 of 112 ...
Page 53: ...53 of 112 ...
Page 55: ...55 of 112 ...