OMNI-Test Laboratories, Inc.
Control No. C-SFAK-0001, Effective date: 12/2/2015
Page 1 of 1
DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET
Instrument to be calibrated: Pressure Transducer______________
Maximum Range: 0-2” WC
ID Number: OMNI-00336
Calibration Instrument: Digital Manometer
ID Number: OMNI-00395
Date: 1/17/2018
By: B. Davis
This form is to be used only in conjunction with Standard Procedure C-SPC.
*Acceptable tolerance is 4%.
The uncertainty of measurement is ±0.4” WC. This is based on the reference standard having a TAR (Test
Accuracy Ratio) of at least 4:1.
Technician signature:
Date: 1/18/2018
Reviewed by:
Date:
Range of
Calibration Point
(
″WC)
Digital
Manometer
Input
(
″WC)
Pressure Gauge
Response
(
″WC)
Difference
(Input -
Response)
% Error of
Full Span
*
0-20% Max. Range
0 - 0.4
0.35
0.362
0.012
0.6
20-40% Max. Range
0.4 - 0.8
0.65
0.672
0.022
1.1
40-60% Max. Range
0.8 – 1.2
1.00
1.024
0.024
1.2
60-80% Max. Range
1.2 – 1.6
1.30
1.340
0.040
2.0
80-100% Max. Range
1.6 – 2.0
1.70
1.749
0.049
2.45
1/19/2018
49 of 112
Summary of Contents for PP130-B
Page 15: ...1445 North Hwy Colville WA 99114 800 234 2508 Low 15 of 112 ...
Page 28: ...28 of 112 ...
Page 29: ...29 of 112 ...
Page 33: ...33 of 112 ...
Page 35: ...35 of 112 ...
Page 36: ...36 of 112 ...
Page 37: ...37 of 112 ...
Page 38: ...38 of 112 ...
Page 39: ...39 of 112 ...
Page 41: ...41 of 112 ...
Page 42: ...42 of 112 ...
Page 43: ...43 of 112 ...
Page 44: ...44 of 112 ...
Page 47: ...1 19 2018 47 of 112 ...
Page 50: ...1 19 2018 50 of 112 ...
Page 51: ...51 of 112 ...
Page 52: ...52 of 112 ...
Page 53: ...53 of 112 ...
Page 55: ...55 of 112 ...