OMNI-Test Laboratories, Inc.
BR – Average dry burn rate over full integrated test run, kg/hr
ASTM E2779 equation (3)
60 M
Bdb
θ
Where,
θ
= Total length of full intergrated test run, min
Sample Calculation:
M
Bdb
= 5.57
kg
θ
= 360
min
60 x 5.57
BR
=
0.93
BR
=
360
kg/hr
BR
=
Control No. P-SFDK-0002, Effective date: 5/06/2016