background image

OMNI-Test Laboratories, Inc.

BR – Average dry burn rate over full integrated test run, kg/hr

ASTM E2779 equation (3)

60 M

Bdb

θ

Where, 

θ

= Total length of full intergrated test run, min

Sample Calculation:

M

Bdb

= 5.57

kg

θ

= 360

min

60 x  5.57

BR

=

0.93

BR

=

360

kg/hr

BR

=

Control No. P-SFDK-0002,  Effective date:  5/06/2016

File - 135PS040E PP70 Run 1, Tab - Example Calculations

60 of 112

Summary of Contents for PP130-B

Page 1: ...a and information contained in this report are confidential and proprietary to Hearth and Home Technologies Its significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests examinations or surveys made The contents of this report cannot be copied or quoted except in full without specific written authorization from Hearth and Home Tec...

Page 2: ... has been reviewed and approved by the following authorized signatories Evaluation Decision __________________________ Bruce Davis Technician OMNI Test Laboratories Inc Evaluation Decision __________________________ Ken Morgan Testing Manager OMNI Test Laboratories Inc ______________ Issue Date 2 of 112 June 7 2018 ...

Page 3: ...ble 1 2 Efficiency and CO p 7 Table 1 3 Test Facility Conditions p 8 Table 1 4 Fuel Measurement Summary p 8 Table 1 5 Dilution Tunnel and Flue Gas Measurements p 9 Table 1 6 Heater Configuration p 9 2 PHOTOGRAPHS APPLIANCE DESCRIPTION DRAWINGS p 10 Photographs p 11 Appliance Description p 12 3 TEST DATA BY RUN p 13 Run 1 p 16 4 QUALITY ASSURANCE QUALITY CONTROL p 30 Sample Analysis p 32 Calibratio...

Page 4: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Section 1 Sampling Procedures and Test Results 4 of 112 ...

Page 5: ... s submitted SAMPLING PROCEDURE The PP130 B was tested in accordance with the U S EPA 40 CFR Part 60 Subpart AAA Standards of Performance for New Residential Wood Heaters using ASTM E2515 and ASTM E2779 The fuel used for certification testing was Lignetics pellet fuel this fuel was graded as Premium by the Pellet Fuels Institute and was produced at registered mill 03208 Particulate emissions were ...

Page 6: ...on factor for the complete integrated test run was measured to be 0 50 g dry kg of fuel The average thermal efficiency for the complete integrated test run was measured to be 81 9 The particulate emission rate calculated from the one hour filter was 0 96 g hr The proportionality results and sample train agreement for the test run was acceptable Quality check results for each test run are presented...

Page 7: ...0 53 Emission Factor g dry kg 0 38 0 50 Table 1 2 Efficiency and CO Burn Rate Segment Integrated Total Maximum Medium Minimum Time minutes 60 120 180 360 Burn Rate dry kg hr 2 53 1 03 0 60 1 06 Heat Output Rate BTU hr 40 637 15 929 9 605 16 968 Heat Input Rate BTU hr 49 207 20 017 11 676 20 712 Efficiency HHV 82 6 79 6 82 3 81 9 CO Emission Rate g min 0 0383 0 150 0 215 0 160 7 of 112 ...

Page 8: ...etric Pressure in Hg 30 40 30 44 Air Velocity ft min 50 50 Induced Draft in H2O 0 0 0 0 Table 1 4 Fuel Measurement Summary Segment Time min Burn Rate dry kg hr Consumed Fuel Weight lbs Fuel Moisture Content dry basis Pretest 60 2 48 5 8 5 91 Maximum 60 2 53 5 9 5 91 Medium 120 1 03 4 8 5 91 Minimum 180 0 60 4 2 5 91 Integrated Total 360 1 06 14 9 5 91 8 of 112 ...

Page 9: ...Segment Average Flue Draft in H2O Average Dilution Tunnel Gas Measurements Velocity ft sec Flow Rate dscf min Temperature F Integrated Total 0 034 14 69 167 4 84 Table 1 6 Heater Configuration Segment Heat Setting Control Knob Trim Setting Power Level Shown in Program Pretest Hi 4 5 Maximum Hi 4 5 Medium 3 3 2 Minimum Lo 0 1 9 of 112 ...

Page 10: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Section 2 Photographs Appliance Description Drawings 10 of 112 ...

Page 11: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Hearth and Home Technologies PP130 B PHOTOGRAPHS PP130 B Front PP130 B Back PP130 B Left PP130 B Control Knob 11 of 112 ...

Page 12: ...r to the burn pot via an auger that carries pellets up from the hopper to a drop tube that routs pellets into the burn pot Fuel supply rate is varied by cycling the auger motor on off time as needed for desired heat output settings A door located on the front of the appliance is used primarily for cleaning and servicing the fire pot A 5mm thick ceramic glass panel is utilized for viewing the fire ...

Page 13: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Section 5 Test Data by Run 13 of 112 ...

Page 14: ...be set to 10 and the trim pot should be set to 4 When the unit is set and running at this setting the light above the dial control will Flash 5 times with a pause between each sequence Medium Dial should be set to 3 and the trim pot should be set to 3 When the unit is set and running at this setting the light above the dial control will flash 2 times with a pause between each sequence Low Dial sho...

Page 15: ...1445 North Hwy Colville WA 99114 800 234 2508 Low 15 of 112 ...

Page 16: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Run 1 16 of 112 ...

Page 17: ...9 264 21 5 7 262 22 5 9 261 23 5 9 258 24 5 9 260 25 5 9 258 26 6 0 260 27 5 9 259 28 5 8 258 29 5 8 258 30 5 7 258 31 5 8 258 32 5 8 258 33 5 7 257 34 5 7 272 35 6 1 211 36 5 9 293 37 6 1 291 38 5 9 286 39 6 0 284 40 6 1 285 41 6 0 284 42 6 0 282 43 6 0 284 44 6 0 283 45 6 0 284 46 6 0 283 47 6 0 282 48 5 9 280 49 5 8 278 50 5 7 279 Project No 0135PS041E Test Date March 2018 II III IV Manufacture...

Page 18: ... 20 24 6 0 5 298 70 0 05 10 38 0 00 5 25 24 1 0 5 302 71 0 05 9 31 0 00 6 30 23 7 0 4 294 72 0 05 10 49 0 00 7 35 23 2 0 5 294 70 0 05 11 19 0 01 8 40 22 7 0 5 297 71 0 05 0 96 0 09 9 45 22 2 0 5 302 71 0 05 11 30 0 02 10 50 21 7 0 5 299 71 0 05 9 35 0 00 11 55 21 2 0 5 301 72 0 05 10 26 0 00 12 60 20 8 0 4 293 71 0 05 9 00 0 00 13 14 15 Averages Hearth Home PP130B 2266 0135PS041E 3 26 2018 Manufa...

Page 19: ...461 60 9 717 9 359 0 16 0 16 1 31 81 1 96 1 06 82 1 1 98 0 060 100 99 14 9 0 5 300 75 75 72 0 052 5 24 0 00854 65 10 533 10 138 0 16 0 16 1 32 82 1 94 1 06 83 1 1 95 0 061 100 98 14 6 0 3 264 76 75 71 0 047 4 62 0 01395 70 11 347 10 918 0 16 0 16 1 32 82 1 94 1 05 83 1 1 92 0 060 100 99 14 4 0 2 239 75 74 72 0 042 3 63 0 01334 75 12 163 11 699 0 16 0 16 1 32 82 1 95 1 05 83 1 1 91 0 061 99 98 14 3...

Page 20: ...5 72 72 70 0 027 3 5 0 02591 225 36 969 35 813 0 17 0 16 1 36 83 2 1 10 83 1 2 75 0 062 98 98 9 1 0 1 149 72 71 70 0 025 2 18 0 06103 230 37 797 36 617 0 17 0 16 1 36 82 1 99 1 09 82 1 2 75 0 062 98 99 9 0 0 1 148 71 71 70 0 026 3 04 0 0411 235 38 625 37 420 0 17 0 16 1 36 82 1 99 1 10 82 1 2 74 0 062 98 98 8 9 0 1 146 71 71 70 0 025 4 09 0 01687 240 39 453 38 223 0 17 0 16 1 37 82 2 1 09 82 1 2 7...

Page 21: ...8 98 98 98 F Vstrav 14 83 ft sec Vscent 16 56 ft sec Fp 0 896 Particulate Sampling Data Elapsed Time min Gas Meter 1 ft 3 Gas Meter 2 ft 3 Sample Rate 1 cfm Sample Rate 2 cfm Orifice dH 1 H2O Meter Temp 1 F Meter Vacuum 1 Hg Orifice dH 2 H2O Meter Temp 2 F Meter Vacuum 2 Hg Dilution Tunnel F Dilution Tunnel Center dP Pro Rate 1 Pro Rate 2 Scale Reading Weight Change Stack Filter 1 Filter 2 Ambient...

Page 22: ...Sub Total Total Particulate mg 2 3 Train 1 Aggregate Total Particulate mg 3 2 TRAIN 2 Sample Component Reagent Filter Probe Weights or Dish Final mg Tare mg Particulate mg A Front filter catch Filter D472 119 3 116 4 2 9 B Rear filter catch Filter D473 116 2 116 2 0 0 C Probe catch Probe 30 114329 1 114329 2 0 0 D Filter seals catch Seals R575 3381 4 3381 1 0 3 Total Particulate mg 3 2 AMBIENT Sam...

Page 23: ...3 2 mg 3 2 mg 0 9 mg Particulate Concentration dry standard Cr Cs 0 000004 grams dscf 0 00006 grams dscf 0 00006 grams dscf 0 00010 grams dscf Total Particulate Emissions ET 0 22 grams 3 13 grams 3 24 grams 0 96 grams Particulate Emission Rate 0 04 grams hour 0 52 grams hour 0 54 grams hour 0 96 grams hour Emissisons Factor 0 49 g kg 0 51 g kg 0 38 g kg Difference from Average Total Particulate Em...

Page 24: ...ut Rate kJ h 17 887 16 968 Btu h Burn Rate kg h 1 06 2 34 lb h Input kJ h 21 834 20 712 Btu h Test Load Weight dry kg 6 38 14 07 dry lb MC wet 5 580209612 MC dry 5 91 Particulate g 3 18 CO g 58 Test Duration h 6 00 Emissions Particulate CO g MJ Output 0 03 0 54 g kg Dry Fuel 0 50 9 07 g h 0 53 9 65 lb MM Btu Output 0 07 1 25 Air Fuel Ratio A F 27 02 VERSION 2 2 12 14 2009 OMNI Test Laboratories Te...

Page 25: ...put Rate kJ h 42 838 40 637 Btu h Burn Rate kg h 2 53 5 57 lb h Input kJ h 51 873 49 207 Btu h Test Load Weight dry kg 2 53 5 57 dry lb MC wet 5 580209612 MC dry 5 91 Particulate g 0 CO g 2 Test Duration h 1 00 Emissions Particulate CO g MJ Output 0 00 0 05 g kg Dry Fuel 0 00 0 93 g h 0 00 2 34 lb MM Btu Output 0 00 0 13 Air Fuel Ratio A F 12 99 VERSION 2 2 12 14 2009 OMNI Test Laboratories Test R...

Page 26: ...ut Rate kJ h 16 792 15 929 Btu h Burn Rate kg h 1 03 2 27 lb h Input kJ h 21 101 20 017 Btu h Test Load Weight dry kg 2 06 4 53 dry lb MC wet 5 580209612 MC dry 5 91 Particulate g 0 CO g 18 Test Duration h 2 00 Emissions Particulate CO g MJ Output 0 00 0 53 g kg Dry Fuel 0 00 8 74 g h 0 00 8 98 lb MM Btu Output 0 00 1 24 Air Fuel Ratio A F 29 61 VERSION 2 2 12 14 2009 OMNI Test Laboratories Test R...

Page 27: ...ut Rate kJ h 10 125 9 605 Btu h Burn Rate kg h 0 60 1 32 lb h Input kJ h 12 309 11 676 Btu h Test Load Weight dry kg 1 80 3 97 dry lb MC wet 5 580209612 MC dry 5 91 Particulate g 0 CO g 39 Test Duration h 3 00 Emissions Particulate CO g MJ Output 0 00 1 28 g kg Dry Fuel 0 00 21 57 g h 0 00 12 94 lb MM Btu Output 0 00 2 97 Air Fuel Ratio A F 39 63 VERSION 2 2 12 14 2009 OMNI Test Laboratories Test ...

Page 28: ...28 of 112 ...

Page 29: ...29 of 112 ...

Page 30: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Section 4 Quality Assurance Quality Control 30 of 112 ...

Page 31: ...roduct safety testing as a Certification Organization by the Standards Council of Canada SCC Serving as a testing laboratory for the certification of wood heaters by the U S Environmental Protection Agency This report is issued within the scope of OMNI s accreditation Accreditation certificates are available upon request The manufacturing facilities and quality control system for the production of...

Page 32: ...PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Sample Analysis Analysis Worksheets Moisture Content Worksheet Fuel Certification Label Tared Filter Probe and O Ring Data 32 of 112 ...

Page 33: ...33 of 112 ...

Page 34: ...SO 1928 GJ tonne 19 20 17 99 Net Cal Value at Const Pressure ISO 1928 J g 19197 17989 Gross Cal Value at Const Vol ASTM E711 J g 20523 19377 Gross Cal Value at Const Vol ASTM E711 Btu lb 8824 8331 Carbon ASTM D5373 wt 50 70 47 87 Hydrogen ASTM D5373 wt 6 09 5 75 Nitrogen ASTM D5373 wt 0 20 0 19 Oxygen ASTM D3176 wt 42 66 40 27 Note As received values do not include hydrogen and oxygen in the total...

Page 35: ...35 of 112 ...

Page 36: ...36 of 112 ...

Page 37: ...37 of 112 ...

Page 38: ...38 of 112 ...

Page 39: ...39 of 112 ...

Page 40: ...rd 283A Audit Weights Troemner 21pc Msas Set Calibration Certificate 335 Sample Box Dry Gas Meter Apex Automated Emissions Sampling Box Calibration Log 336 Sample Box Dry Gas Meter Apex Automated Emissions Sampling Box Calibration Log 410 Microtector Dwyer Microtector Calibration Certificate 559 Vaneometer Dwyer Vaneometer Equipment Record 592 Thermohygrometer Omega Digital Thermohygrometer Calibr...

Page 41: ...41 of 112 ...

Page 42: ...42 of 112 ...

Page 43: ...43 of 112 ...

Page 44: ...44 of 112 ...

Page 45: ...bration Parameters Run 1 Run 2 Run 3 Reference Meter Pressure H2O Pr 0 00 0 00 0 00 DGM Pressure H2O Pd 2 30 1 38 1 00 Initial Reference Meter 198 1 203 7 214 2 Final Reference Meter 203 602 208 8 222 5 Initial DGM 0 0 0 Final DGM 5 65 5 298 8 67 Temp Ref Meter F Tr 68 1 68 1 68 0 Temperature DGM F Td 77 0 78 0 80 0 Time min 26 5 31 8 43 5 Net Volume Ref Meter Vr 5 502 5 100 8 300 Net Volume DGM V...

Page 46: ...dure C SPC Acceptable tolerance is 4 The uncertainty of measurement is 0 4 WC This is based on the reference standard having a TAR Test Accuracy Ratio of at least 4 1 Technician signature Date 1 18 2018 Reviewed by Date Range of Calibration Point WC Digital Manometer Input WC Pressure Gauge Response WC Difference Input Response Error of Full Span 0 20 Max Range 0 0 4 0 08 0 067 0 013 0 65 20 40 Ma...

Page 47: ...1 19 2018 47 of 112 ...

Page 48: ...ation Parameters Run 1 Run 2 Run 3 Reference Meter Pressure H2O Pr 0 00 0 00 0 00 DGM Pressure H2O Pd 1 95 1 20 0 80 Initial Reference Meter 223 4 231 9 238 Final Reference Meter 231 7 237 9 243 503 Initial DGM 0 0 0 Final DGM 8 517 6 215 5 713 Temp Ref Meter F Tr 68 0 69 1 68 6 Temperature DGM F Td 76 0 78 0 79 0 Time min 39 8 36 5 37 0 Net Volume Ref Meter Vr 8 300 6 000 5 503 Net Volume DGM Vd ...

Page 49: ...edure C SPC Acceptable tolerance is 4 The uncertainty of measurement is 0 4 WC This is based on the reference standard having a TAR Test Accuracy Ratio of at least 4 1 Technician signature Date 1 18 2018 Reviewed by Date Range of Calibration Point WC Digital Manometer Input WC Pressure Gauge Response WC Difference Input Response Error of Full Span 0 20 Max Range 0 0 4 0 35 0 362 0 012 0 6 20 40 Ma...

Page 50: ...1 19 2018 50 of 112 ...

Page 51: ...51 of 112 ...

Page 52: ...52 of 112 ...

Page 53: ...53 of 112 ...

Page 54: ...A N A Calibrate Prior to use OMNI in house CAI ZRE 4 Gas Analyzer OMNI 00594 CO2 O2 and dual range CO gas analyzer ZRE 4 Check X for answer 1 Complete Calibration documentation 2 Complete top half of this form 3 Attach appropriate calibration forms and save in following location omni serv Test Equipment Equipment OMNI XXXXX Equipment Name 4 Repopulate database with updated information 5 Print lami...

Page 55: ...55 of 112 ...

Page 56: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Example Calculations 56 of 112 ...

Page 57: ...tunnel gas velocity ft sec Cs Concentration of particulate matter in tunnel gas dry basis corrected to standard conditions g dscf Particulate concentration g dscf ET Total Particulate Emissions g Dilution tunnel gas flow rate dscf min PR Proportional Rate Variation Particulate emission rate lbs hr PMR Average particulate emissions for full integrated test run g hr Total particulate emissions grams...

Page 58: ...Swb weight of test fuel in hopper at start of test run wet basis kg MEwb weight of test fuel in hopper at end of test run wet basis kg Sample Calculation 5 9 MSwb 41 5 lbs MEwb 28 5 lbs 0 4536 Converstion factor from lbs to kg MBdb 41 5 x 0 4536 28 5 x 0 4536 100 100 5 91 MBdb 5 6 kg Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calculations 58 of 112 ...

Page 59: ...f test run segment i wet basis kg MESiwb weight of test fuel in hopper at end of test run segment i wet basis kg Sample Calculation from medium burn rate segment FM 5 9 MSSiwb 36 4 lbs MESiwb 32 7 lbs 0 4536 Converstion factor from lbs to kg MBSidb 36 4 x 0 4536 32 7 x 0 4536 100 100 6 MBSidb 1 6 kg Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calculations ...

Page 60: ...run kg hr ASTM E2779 equation 3 60 MBdb θ Where θ Total length of full intergrated test run min Sample Calculation MBdb 5 57 kg θ 360 min 60 x 5 57 BR 0 93 BR 360 kg hr BR Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calculations 60 of 112 ...

Page 61: ...9 equation 4 60 MBSidb θSi Where θSi Total length of test run segment i min Sample Calculation from medium burn rate segment MBSidb 1 58 kg θ 120 min 60 x 1 58 BR 0 79 BR 120 kg hr BRSi Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calculations 61 of 112 ...

Page 62: ...H20 in Hg in H20 13 6 Ms The dilution tunnel wet molecular weight Ms 28 78 assuming a dry weight of 29 lb lb mole Sample calculation 14 33 15 59 81 7 1 2 Vs 0 919 x 85 49 x 0 99 x 0 241 x 0 20 13 6 Vs 14 73 ft s The ASTM test standard mistakenly has the square root of the average delta p instead of the average of the square root of delta p The current EPA Method 2 is also incorrect This was verifi...

Page 63: ...el ft2 Tstd Standard absolute temperature 528 R Ps Absolute average gas static pressure in diltuion tunnel Pbar Pg in Hg Ts Absolute average gas temperature in the dilution tunnel R R F 460 Pstd Standard absolute pressure 29 92 in Hg Sample calculation 0 20 13 6 81 7 460 Qsd dscf hr 29 92 14 73 x 0 196 30 5 Qsd 3600 x 1 0 02 x x 528 x std s s std s ws sd P P T T A v B Q 1 3600 Control No P SFDK 00...

Page 64: ...orifice meter in H2O Tm Absolute average dry gas meter temperature R Sample Calculation Using equation for Train 1 1 33 Vm std 17 64 x 59 062 x 0 977 x 13 6 82 2 460 Vm std 57 456 dscf Using equation for Train 2 1 04 Vm std 17 64 x 57 071 x 0 979 x 13 6 82 5 460 Vm std 55 560 dscf Using equation for ambient train 0 00 Vm std 17 64 x 55 10 x 0 997 x 13 6 73 3 460 Vm std 55 430 dscf 30 51 30 51 30 5...

Page 65: ...ass of particulate matter from filter seals mg Sample Calculation Using equation for Train 1 first hour mn 0 0 0 9 0 0 mn 0 9 mg Using equation for Train 1 remainder mn 0 0 1 5 0 3 mn 1 8 mg Train 1 Aggregate 2 7 mg Using equation for Train 2 mn 0 0 2 8 0 0 mn 2 8 mg g f p n m m m m Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calculations 65 of 112 ...

Page 66: ...er collected in the sampling train mg Vm std Volume of gas sampled corrected to dry standard conditions dscf Sample calculation For Train 1 2 7 57 46 Cs 0 00005 g dscf For Train 2 2 8 55 56 Cs 0 00005 g dscf For Ambient Train 0 0 55 43 Cr 0 000000 g dscf Cs 0 001 x Cs 0 001 x Cr 0 001 x 2 std m n s V m K C Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calcul...

Page 67: ...al time of test run minutes Sample calculation For Train 1 ET 0 000047 0 000000 x x 360 60 ET 2 86 g For Train 2 ET 0 000050 0 000000 x x 360 60 ET 3 06 g Average E 2 96 g Total emission values shall not differ by more than 7 5 from the total average emissions 7 5 of the average 0 22 Train 1 difference 0 10 Train 2 difference 0 10 std r s T Q c c E Control No P SFDK 0002 Effective date 5 06 2016 F...

Page 68: ...on tunnel ft sec Tmi Absolute average dry gas meter temperature during the ith time interval o R Tm Absolute average dry gas meter temperature o R Tsi Absolute average gas temperature in the dilution tunnel during the ith time interval o R Ts Absolute average gas temperature in the dilution tunnel o R Sample calculation for the first 1 minute interval of Train 1 360 x 1 615 x 14 73 x 93 0 460 x 82...

Page 69: ...uation 5 PMR 60 ET θ Where ET Tota particulate emissions grams θ Total length of full intergrated test run min Sample Calculation ET Dual train average 2 96 g θ 360 min PMR 60 x 2 96 360 PMR 0 49 g hr Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calculations 69 of 112 ...

Page 70: ...2779 equation 6 PMF ET MBdb Where ET Tota particulate emissions grams MBdb Weight of test fuel burned during test run dry basis kg Sample Calculation ET Dual train average 2 96 g MBdb 5 57 kg PMF 2 96 5 57 PMF 0 53 g kg Control No P SFDK 0002 Effective date 5 06 2016 File 135PS040E PP70 Run 1 Tab Example Calculations 70 of 112 ...

Page 71: ...Model PP 130 B Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 Section 5 Labeling Owner s Manual s 71 of 112 ...

Page 72: ... BurningType UM 84 HUD FOR USE ONLY WITH PELLETIZED WOOD FUEL Do not use any other type of fuel Input Rating 49 207 Btu s hr Electrical Rating 120 VAC 60 Hz Start 2 6 Amps Run 2 3 AMPS Route power cord away from unit Do not route cord under or in front of appliance Do not obstruct the space beneath the heater DANGER Risk of electrical shock Disconnect power supply before servicing Replace glass on...

Page 73: ...d result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Note To obtain a French translation of this manual please contact your dealer or visit www pelprostoves com Pour obtenir une traduction francaise de ce manuel s il vous plait contracter votre revendeur ou visitez www pelprostoves ...

Page 74: ...ll any component not approved by the manufacturer Install parts or components not listed or approved Disable safety switches Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or your dealer DANGER HOT SURFACES Glass and other surfaces are hot during operation A...

Page 75: ...F TO 350 F B CHG MIN MAX TO HI LO AUTOMATIC TO COMFORT LEVEL ADD LOGO UPDATE BACKGROUND COLORING C BACKGROUND AND COPY NOTE UPDATD D GROUPED LANGUAGES REMOVED PHONE NUMBER L appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel se ha The appliance will run continuous...

Page 76: ...osen the three retaining bolts on the back of the Stove and remove the right and left side panels 2 Using a 5 16 inch wrench on each side of the Stove remove the two bolts Remove shipping brackets by reaching into Stove in the same area as the just removed bolts APPAREILS À GRANULÉS PP130 Appareil à granulés Manuel du propriétaire AVERTISSEMENT Veuillez lire entièrement ce manuel avant l installat...

Page 77: ... PL vent Use 4 diameter vent if flue height is over 15 or if installation is over 3 000ft above sea level Gloves Safety glasses Close toed shoes Floor Protection Non combustible material such as a hearth pad is required underneath your Stove Surge Protector Protect the electrical components of your Stove by using a surge protector Pellet Fuel Use only wood pellets in your Stove For best performanc...

Page 78: ...h as Wood Sheet rock drywall Carpet A A B B G E D Getting Ready 1 2 3 WARNING Asphyxiation Risk DO NOT INSTALL IN A SLEEPING ROOM Consumes oxygen in the room Pro Tip We highly recommend your Stove and pellet vent pipe be installed by a professional installer Your retailer can make recommendations for you Installation MUST comply with local regional state and national codes and regulations Consult ...

Page 79: ... exhaust venting system of this Stove Do not connect this Stove to a chimney flue serving another Stove The structural integrity of the manufactured home floor wall and ceiling roof must be maintained Pro Tip This Stove can be installed with a 3 to 6 inch 76 152mm Top Vent Offset Adapter Kit The 3 to 6 inch 76 152mm Top Vent Offset Adapter are tested to use 24 gauge single wall flue connector or L...

Page 80: ...ulator assembly Clearance to each side of center line extended above natural gas or propane meter regulator assembly or mechanical vent NOTICE Do NOT terminate vent In any location that will allow flue gases or soot from entering or staining the building In any location which could create a nuisance or hazard In any enclosed or semi enclosed area such as a carport garage attic crawl space under a ...

Page 81: ...firm required clearances to combustibles 3 Vertical Installations Interior Flue Straight back against wall Inches mm D Back wall to pellet pipe 3 254 E Side wall to Stove 13 330 USA Hearth Pad Requirements Inches mm A Sides 2 51 B Back 2 51 C Front 6 152 Horizontal Installations Straight back against wall Inches mm G Back wall to Stove 2 51 E Side wall to Stove 13 330 Corner Installation Straight ...

Page 82: ...home exterior WARNING Do not terminate venting in any enclosed or semi enclosed area such as a carport garage attic crawl space under a sun deck or porch narrow walkway or closely fenced area or any location that can build up a concentration of fumes such as a stairwell covered breezeway etc CAUTION Ensure that your Stove venting terminates above your Stove The following may occur Your Stove will ...

Page 83: ...ength of Horizontal Sections ft Minimum Vertical Rise ft Minimum Vertical Vent for Two Elbows Length of Horizontal Sections FT ONE 90 ELBOW Total Horizontal Minimum Vertical Vent Diameter 4 0 3 5 5 3 6 6 3 7 7 3 8 8 4 9 9 4 10 10 4 11 11 4 12 12 4 13 13 4 14 14 4 15 15 4 16 16 4 17 17 4 18 18 4 19 19 4 TWO 90 ELBOWS Total Horizontal Minimum Vertical Vent Diameter 2 5 3 3 6 3 4 7 3 5 8 3 6 9 3 7 10...

Page 84: ...ate fasteners Take a Break Inspect your work _____ Confirm clearances to combustibles are maintained _____ Pipe joints are secure and properly sealed _____ Outside air kit installed properly _____ Confirm termination clearances 6 B CAUTION Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic garage or crawl space Install pellet venting through wall an...

Page 85: ...products Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pellets Lower Ash Content Material Most softwoods Fuels with low mineral content Most premium grade pellets Fuel Tips Pro Tip We recommend the use of Pellet Fuels Institute certified pellet fuel ...

Page 86: ...nvection blower will continue to run even after your Stove has been shut down Pro Tips Odors and vapors are released during initial startup after purchase burning your Stove on HI for 30 minutes will allow the paint to cure Open windows or doors for air circulation until burn off is complete During start up and normal operation your Stove s front door must be closed Priming is only required the fi...

Page 87: ...receptacle Do NOT route cord under or in front of Stove Recommend the use of a surge protector 3 3 1 1 2 2 2 2 3 3 Confirm three baffles inside firebox are secure placing the side baffles before the center Add some pellets to hopper and fully close lid Confirm fire pot is properly positioned Using Your Stove 4 2 1 4 3 5 6 7 8 9 10 LO OFF HI 0 1 2 3 4 1 2 3 4 O N AUTO AL A R M 2 1 4 3 5 6 7 8 9 10 ...

Page 88: ...en once per second 2 1 4 3 5 6 7 8 9 10 LO OFF HI 0 1 2 3 4 1 2 3 4 O N AUTO AL A R M 2 1 4 3 5 6 7 8 9 10 LO OFF HI 6 3 7 7 Prime your Stove 1 Quickly turn the dial control from OFF to HI 2 Back to OFF 3 Then back to HI The feed motor will run continuously for two minutes and the LED light will be solid green Once primed pellets will drop into the fire pot and the LED light will blink green as ig...

Page 89: ... clean the fire pot Your Stove is now ready to resume normal use What Do the Blinking Lights Mean Green Amber Normal Operation Green Steady On Feed system is priming Green 1 Blink Stove is off and ready Green Continuous Blinking Stove is in the start up ignition sequence Green Varies Blinks Varies depending on burn rate Amber Steady On Stove is set and running at either the minimum or maximum powe...

Page 90: ...ll go through the shutdown process approximately 15 minutes and restart Thermostat Your PelPro Stove comes with a built in thermostat system that provides easy temperature adjustments The Stove is not designed to use a remote control or external thermostat Trim Adjustment HI setting Your Stove will continue to run on high regardless of room temperature LED light will be steady amber Trim Adjustmen...

Page 91: ... 5 6 7 8 9 10 LO OFF HI 1 3 2 5 4 Turn dial to OFF position Auger stops feeding pellets Blowers continue to run until after the exhaust temperature has cooled Turning Your Stove Off CAUTION Smoke Hazard Turn dial control to OFF let Stove completely cool and exhaust blower must be off Now you can unplug Stove before servicing Smoke spillage into room can occur if Stove is not cool before unplugging...

Page 92: ... abrasive cloth Ash vacuum Drop cloth Gloves Safety glasses Cleaning tool Cleaning Maintenance Important Regular cleaning helps to assure optimal performance of your Stove Please refer to page 29 to log your maintenance and cleaning Cleaning your Stove Visit pelprostoves com or scan this code Phillips head screwdriver Maintaining your Stove Visit pelprostoves com or scan this code 92 of 112 ...

Page 93: ...r otherwise locally dispersed they should be retained in the closed container until all cinders have been thoroughly cooled Zone 1 Firebox Fire pot Remove the fire pot Scrape clean and remove ashes Replace fire pot Firebox Remove baffles and vacuum residual ash Remove ashes from firebox floor Glass Apply ceramic glass cleaner Use non abrasive cloth to remove residue WEEKLY AS NEEDED OR Door Inspec...

Page 94: ... Avoid striking scratching or slamming glass Do NOT clean glass when hot Do NOT use abrasive cleaners Do NOT operate with glass cracked broken or scratched Pro Tip The type of fuel you are burning will dictate how often you have to clean your fire pot If the fuel you are burning has a high dirt or ash content it may be necessary to clean the fire pot more than once a day Poor quality fuel will cau...

Page 95: ...h to remove ash and buildup from the venting Outside Air Kit Ensure there are no obstructions in the outside air kit cap ANNUALLY AS NEEDED OR ANNUALLY AS NEEDED OR Caution When wood pellets are burned at a low temperature they produces organic vapors which combine with moisture to form creosote vapors Creosote vapors condense in the relatively cool chimney flue of a newly started or a low tempera...

Page 96: ...generator for best Stove performance This Stove needs 110v to run properly This Stove has not been tested for use with a third party battery backup Stove plugged in but no response Unplug your Stove Check your home s circuit breaker Reset snap disc located between drop tube and hopper Zone 2 Visually inspect wires blowers and power cord for breaks or wear to find cause of possible short circuit Zo...

Page 97: ... panel to access and confirm vacuum switch is clear and connected at both ends Confirm all exhaust blower connections secure Confirm the feed assembly and motor are clean and clear of debris Confirm exhaust path is clean and clear Zone 3 1 Zone 1 Zone 3 Zone 3 Zone 2 Zone 2 Zone Blockage Related Black soot on outside of house Confirm exhaust path is clean and clear Zone 1 and 3 Adjust air fuel rat...

Page 98: ... and stops frequently in automatic mode Determine if your room is experiencing varying temperatures due to repeated opening closing of doors or windows correct if necessary Examine Stove body Zone 2 Inspect ambient probe and confirm that at least 2 is exposed outside of Stove body Slow or smoky start up and or lazy flame Confirm exhaust path is clean and clear Zone 3 Examine Stove body Zone 2 Alig...

Page 99: ... circuit Replace control board and failed component Stove fails to shut off Stove running in maximum or minimum Turn dial control to Off position See Also Feed Motor Does Not Shut Off The Stove should go into a shutdown Large lazy flame orange color Black ash on glass Dirty Stove Poor fuel quality high ash content Incorrect air fuel adjustment Excessive feeding Feed Motor locked on Clean Stove inc...

Page 100: ...obe into the board Replace the component 4 Flashes Missed Ignition During the ignition sequence the load does not ignite The Stove will automatically retry once from the first failed attempt Fuel No fuel Hopper Empty Feed Jam Feed doesn t turn Feed motor disconnected or failed Fire pot Fire pot Dirty so fuel is not near ignition hole in the fire pot Igniter No power Debris in the end of the ignite...

Page 101: ...he date of purchase Retain your original receipt as proof of purchase The warranty period for covered components is as follows Additional terms and limitations apply See page 28 for complete warranty information Components Covered Warranty Period Parts only Labor not included Electrical 1 Year Steel Parts excluding fire pot 5 Years All replacement parts are covered for remainder of original warran...

Page 102: ...g Your Stove and Troubleshooting sections in this manual Visit pelprostoves com to access Order replacement parts Installation videos Troubleshooting videos Use and care videos Manuals and more To contact a Consumer Care Specialist email us at Info_PelPro hearthnhome com or call 877 427 3316 102 of 112 ...

Page 103: ... WARNING Asphyxiation Risk DO NOT INSTALL IN A SLEEPING ROOM Your Stove consumes oxygen in the room Note This installation must conform with local codes In the absence of local codes you must comply with ASTM E1509 12 and ULC S627 00 by OMNI Test Laboratories and UM 84 HUD WARNING It is critical to have a working smoke detector installed in the home of Stove operation Smoke alarms that are properl...

Page 104: ...etc This manual describes the installation and operation of the Brand PelPro Model PP130 B wood Stove This Stove meets the 2020 U S Environmental Protection Agency s crib wood emission limits for wood Stoves sold after May 15 2020 Under specific test conditions this Stove has been shown to deliver heat at rates ranging from 9 605 to 40 637 Btu hr BTU Efficiency Specifications Model PP130 B Emissio...

Page 105: ...od for covered components is as follows Parts Service Returns HHT is proud to offer the best technical and sales support in the industry If you have any questions about how to operate your Stove or if you need service parts please visit Pelprostoves com or call 1 877 427 3316 Warranty Exclusions Warranty does not cover damage or breakage due to misuse improper handling or modifications There is no...

Page 106: ...in Left Hand SRV7086 154 3 Exhaust Combustion Blower 812 4400 Y Gasket Between Blower Housing and Stove SRV240 0812 Y Gasket Between Blower Housing and Motor 812 4710 Y 4 Snap disc Manual Reset SRV230 0080 Y 5 Door Assembly SRV7086 021 Y 6 Baf e Kit SRV7077 006 7 Firepot SRV7077 003 Y 8 Igniter Chamber Kit SRV7077 110 9 Igniter Kit SRV7000 660 Y 10 Control Board SRV7077 050 Y 11 Convection Blower ...

Page 107: ...ocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 5 Door Assembly SRV7086 021 Y 5 1 Glass Assembly SRV7081 173 5 2 Rope Door 3 4 x 84 832 1680 5 3 Hinge Pins Pkg of 2 433 1590 2 5 4 Threaded Handle Assembly Kit SRV7093 024 Y 5 5 Handle Black Phenolic Kit KS 5140 1442 Y 16 Feed Assembly Kit SRV7077 014 Y 16 1 Feed Motor SRV7000 670 Y 16 2 Feed Shaft Bushing Pkg of 2 7000 600 2 Y Power Cord 812 1...

Page 108: ...__________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ _________________________________________________________________...

Page 109: ..._________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ___________________...

Page 110: ..._____________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________...

Page 111: ..._____________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________...

Page 112: ...PelPro Pellet Stove 7104 171A 4 20 18 pelprostoves com 40 Hearth Home Technologies 352 Mountain House Road Halifax PA 17032 112 of 112 ...

Reviews: