background image

P/N UMBTSetUpInstructions REV20210811                   

PRODUCT OVERVIEW 

Product Overview 

Your “BT” version scale includes a built-in wireless module. Using the included hardware, the 
scale can transmit data to a Windows

®

 PC or a Welch Allyn

®

 device. See below for set up 

instructions.  
 

Transmitting Data to a Windows

®

 PC 

To allow the scale to wirelessly transmit data to a Windows

®

 PC the scale must first be paired to 

the wireless settings on the user’s PC. See page 6 for more information about the set up for use 
with a PC. Transmitting data into an EMR system requires that the user’s Windows

®

 PC has one 

of the following systems installed: Allscripts TouchWorks

®

 or Professional™, Midmark

®

 

IQmanager

®

 or ChARM Health EHR.  

 

Allscripts Interface:

 To complete the connection to an Allscripts systems, users must 

download the Allscripts app available at www.homscales.com/innovations/connectivity-
solutions. Follow the installation instructions included with the download. To complete 
installation, Allscripts must activate the app within the user’s account to allow for interface 
between the scale and the Allscripts system on the user’s PC.  

 

Midmark Interface: 

Connection between the scale and Midmark IQ Manager requires that 

the user’s PC have the IQ Manager software installed. For further information users must 
contact Midmark Technical Support. 

 

 

ChARM Health EHR Interface:

 ChARM Health users must contact their account manager 

to set up the service. 

 
Transmitting Data to a Welch Allyn Connex Device 

To allow the scale to wirelessly transmit data to a Welch Allyn

®

 Connex

®

 monitor, the included 

hardware must be attached to the Welch Allyn

®

 device. See page 5 for details about connecting 

the scale with WelchAllyn

®

 monitors. From the Welch Allyn

®

 device, data can be transferred into 

an EMR. For data to transfer to the EMR, the EMR installed on the user’s PC must be included 
on the list of Welch Allyn EMR partners. Visit www.welchallyn.com to view a complete list of 
EMR partners. “BT” scales are preconfigured to interface with the following Welch Allyn

®

 

Connex

®

 devices: Connex

®

 Spot Monitor, Connex

®

 Vital Signs Monitors, Connex

®

 Integrated 

Wall Systems.    

 

Health o meter

®

 Professional supports customers who wish to develop interfaces to their EMR and 

other computer systems. Developers can obtain the communication protocols needed for the scale 
models used in their particular environment at www.homscales.com/innovations/connectivity-
solutions. 

 

Windows

®

 PC Requirements

 

  This installation is exclusively compatible with Windows

®

 XP/Vista/7 

  CPU of 1.7GHz and above 

  Minimum 512MB RAM 

  Available USB 2.0 Port 

  Bluetooth

®

 Capable or Bluetooth

®

 Card* 

 

Cautions and Warnings 

 

To prevent installation and performance issues to your PC, please follow these instructions 
carefully. 

 

For accurate data collection, confirm and upload the data according to the procedure 
described in this manual. 

 

Data validation must be confirmed by the user from the scale to the receiving device 
to ensure accurate data collection. 

 

*Bluetooth

®

 is a registered trademark of the Bluetooth Special Interest Group. While Health o meter

®

 Professional scales use 

proprietary technologies for reliably communicating with other devices, it can also be used with many Bluetooth

®

 interfaces.  To 

see if your Bluetooth

®

 device is compatible with the Health o meter

®

 Professional protocols see page 6. 

Summary of Contents for Health o meter Professional weigheasier BT

Page 1: ...P N UMBTSetUpInstructions REV20210811 1 Wireless Communication Set Up Instructions for BT Model Scales PELSTAR LLC 9500 West 55th St McCook IL 60525 7110 USA www homscales com Pelstar LLC 2021 ...

Page 2: ... Health o meter Professional product Please read this manual carefully and keep it for easy reference or training TABLE OF CONTENTS PRODUCT OVERVIEW 3 SET UP FOR WELCH ALLYN CONNEX DEVICE 5 SET UP FOR WINDOWS PC 6 TROUBLESHOOTING 10 REGULATORY INFORMATION 11 WARRANTY 12 ...

Page 3: ...the included hardware must be attached to the Welch Allyn device See page 5 for details about connecting the scale with WelchAllyn monitors From the Welch Allyn device data can be transferred into an EMR For data to transfer to the EMR the EMR installed on the user s PC must be included on the list of Welch Allyn EMR partners Visit www welchallyn com to view a complete list of EMR partners BT scal...

Page 4: ...ting to a Windows PC USB Wireless Dongle Welch Allyn Connex Vital Signs Monitor CVSM Quick Start Guide USB Extender Cable 1 ft Note The serial number on the USB wireless dongle must match the BT device on the label located on the back of the scale display head SERIAL NUMBER AND BT DEVICE NUMBER MUST MATCH TO ENABLE WIRELESS COMMUNICATION USB wireless dongle Label on back of scale display head ...

Page 5: ...cess the Welch Allyn Service Tool This service tool comes with the Welch Allyn device or can be downloaded at www welchallyn com en service support service center service tool html b Follow the prompts in the Service Tool to activate the weight scale license c Activate the license by entering the authorization code A66FF29A3B2F85E1 Note Weight scale communication is already enabled on Welch Allyn ...

Page 6: ...es for reliably communicating with other devices it can also be used with many Bluetooth interfaces To see if your Bluetooth device is compatible with the Health o meter Professional protocols follow these steps 1 From the Start Menu go to Settings 2 In the Settings Home Click on Devices 3 Click on the Bluetooth or other devices ...

Page 7: ... Add a device window will open In the Add a device window click on Bluetooth 5 The PC will search for devices In this window look for the device name starting with HOM followed by the model number of the scale or the word Scales Click on the HOM name to initiate pairing ...

Page 8: ... 8 SET UP FOR WINDOWS PC CONT 6 If pairing is successful it will show as paired Click on Done and the pairing is complete 7 In the main Bluetooth Other Devices window on the right side of the window find and click on More Bluetooth options ...

Page 9: ...DOWS PC CONT 8 The settings window will open In this window click on the COM Ports tab 9 In the COM Ports tab note down the COM Port Number shown next to the HOM Scale Outgoing Use this COM Port COM to communicate with the scale wirelessly to transfer data ...

Page 10: ...h Allyn Connex Fault Symptoms Problem Possible Cause Suggested Action No Weight Height Body Mass Index BMI Displayed on Connex device Weight scale communication license NOT activated on the Connex device Weight scale communication is already enabled on Welch Allyn Connex Spot monitors To enable weight scale communication on the Welch Allyn CVSM follow these steps a Connect the CVSM to a PC to acce...

Page 11: ...lowing two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE REGULATORY BT900 Module The BT900 SA has been tested for compliance with relevant standards for the EU market See table below EU Directives 2014 53 EU Radio Equipment Directive RED Article Number Requirement Refe...

Page 12: ...he product use on improper voltage or current use contrary to the operating instructions abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover natural disasters such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state ...

Reviews: