PDU16-6UK
USERS GUIDE
20A AC STAGE & TRUSS MOUNT PLUG BOARD
For safety it must be remembered when using the LINK output that the
combined load of the 'Daisy Chained' units should not exceed 20A.
POWER INPUT SIDE
LINK OUTPUT SIDE
RED Neon Indicator
If the switch is in the reset position
and lit - this shows there should
be AC power to the board.
Should these
Not
be Lit then -
1st check the power is connected &
none of the outputs are being
overloaded
Neutrik
20A 240V
Blue
PowerCON input connector
For the full 20A usage the
right cable & supply
source should be used
Fitting a 13A plug will
de-rate this board
16A Trip Switch
for the 6 UK sockets
in the event of overload
this will cut the power
LINK OUTPUT
is a grey 20A
PowerCON output connector
and is directly coupled
to the Power Input Socket
not via the breaker circuit