FAN SELECTIONS

Options and Accessories

Construction Accessories

0 =   None

A =   Aluminum curb cap (standard)

F =   Floating hinge kit (aluminum base)

G =  Floating hinge kit (steel base)

H =   Hinged sub-base (aluminum base)

J =   Hinged sub-base (steel base)

S =   Steel curb cap

W =   Wall mounted adaptor

Curb

0 =   None

C =   Curb

Note: Curbs ordered separately on all 

PLOPs

Damper  

00 =  None

D =   Damper

XX =  Special

Extended Lube Lines

0 =   None

L =   Extended lube lines

Guard/Screen

0 =   None

B =   Bird screen

Paint/Coating

0 =   None

F =   Epoxy powder coat (light gray)

G =  Epoxy powder coat with UV 

protection (gray) 

H =   Hi-temp powder coat (black)

J =   Non-stick powder coat (clear)

K  =   Phenolic epoxy powder coat 

(gray)

L =   Phenolic epoxy powder coat with 

UV protection (gray)

N =   Polyester powder coat*

X =   Special

* Colors only available in Polyester 

Powder Coat

Paint Color*

00 =  None

50 =  Chrome green

55 =  Pale green

56 =  Dove gray (PPC standard)

61 =  White

63 =  Oxford beige

65 =  Dover white

66 =  Desert tan

70 =  Black

73 =  Smoke gray

77 =  Brick red

79 =  Peppercorn

81 =  Pale brown

83 =  Chocolate brown

85 =  Timeless bronze

94 =  Charcoal

X =   Special

* Colors only available for polyester 

powder coat

Pedestal

0 =   None

A =   Galvanized pedestal 

B=   Galvanized vented pedestal

C =  Aluminum pedestal 

D =   Aluminum vented pedestal

Spare Belt(s)

0 =   None

1 =   1 spare set

2 =   2 spare set

Special Applications

0 =   None

2 =   Restaurant exhaust (UL762)

4 =   UL heat & smoke  

Special Construction

0 =   None

B =   Spark resistance (AMCA B)

C =   Spark resistance (AMCA C)

D=   Spark resistance (AMCA C) + high 

wind (Miami-Dade)

E=   Spark resistance (AMCA B) + high 

wind (Miami-Dade)

H =   High wind (Miami-Dade)

Stainless Steel

0 =   None

B =   Hardware  & shaft

H =   Hardware

S =   304SS Shaft

X =   Special

Electrical Accessories

Controllers

0 =   None

A =   0-10V output potentiometer

1 =   Lek-Trol solid state speed 

controller (mounted)

2 =   Lek-Trol solid state speed 

controller (loose)

3=   Multi speed controller, iQ-MS 

(ECM only)

4 =   iQ-IPCM-no power supply (ECM 

only)

5 =   iQ-IPCM with 115V/230V power 

supply (ECM only)

6 =   iQ-IPCM with 277V power supply 

(ECM only)

7 =   Provided by others

V =   VFD (belt drive only)

Note: VFD can be ordered separately

Service Switches and ITW*

0 =   None

1 =   NEMA 1 ITW only

3 =   NEMA 3R ITW only

A =   NEMA 1 - loose

C =   NEMA 1 - mounted and wired

D =   NEMA 3R - loose

F =   NEMA 3R - mounted and wired

G =   NEMA 4 - loose

N =   NEMA 7 - loose

Q =   NEMA 9 - loose

X = Special

* ITW - Internal wiring not provided on 

explosion proof motors 

Switches / Sensors

0 =   None

A =   Airminder switch (time delay)

B =   Aifirestat

F =   Firestat switch

Transformer

0 =   None

B =   277Vx115V

Summary of Contents for Fumex

Page 1: ...Upblast Roof Exhausters FUMEX PennBarry Your Single Source for Commercial Industrial Supply Exhaust Fans www pennbarry com PRODUCT GUIDE...

Page 2: ...y com 2 TABLE OF CONTENTS INTRODUCTION 3 CERTIFICATIONS LISTINGS 4 FEATURES BENEFITS 5 6 OPTIONS ACCESSORIES 7 12 MOTOR AVAILABILITY 13 14 DIRECT DRIVE DIMENSIONS 15 BELT DRIVE DIMENSIONS 16 FAN SELEC...

Page 3: ...es Fumex fans feature a weather resistant seamless spun aluminum housing which provides ample drainage and works in conjunction with a patented wheel design and deeply spun inlets to provide smooth qu...

Page 4: ...Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program FX27B is not AMCA Certified cULus Certification Fumex fans carry the UL label UL705 ZACT ZACT...

Page 5: ...ts Vibration Isolators Multidirectional rubber in shear vibration isolators mitigate residual vibration transmission from the unit to the building Structural Integrity Durable housings of spun aluminu...

Page 6: ...rect Drives These enhanced units have Gplus motor selection up to 2 HP available on single phase and three phase and are available up to size 24 Design enhancements to Direct Drive Fumex models signif...

Page 7: ...cy By varying the fan motor input frequency and voltage the VFD controls the motor speed and torque helping to improve productivity and lower energy consumption The VSC and VSA are ideal for both new...

Page 8: ...lt drive models Backdraft Dampers Backdraft dampers are available for either gravity or motorized operation motor kit optional Dampers feature square galvanized steel frames and multi leaf roll formed...

Page 9: ...is constructed from 10 gage galvanized steel and incorporates five torsion springs to automatically position the motor and maintain proper belt tension Additional benefits include reduced belt and pul...

Page 10: ...28 5 27 35 20 19 75 18 FX18BH 28 5 27 35 20 19 75 18 FX24B 33 5 32 40 25 24 75 18 FX24BH 33 5 32 40 25 24 75 18 FX27B and FX30B 36 5 35 43 28 27 75 18 FX36B 44 5 43 51 36 35 5 18 Standard heights H a...

Page 11: ...o the housing exterior An appropriately sized service switch is commonly selected as an additional option These items meet the code requirements for positive electric shut off Grease Collector Separat...

Page 12: ...he additional 45 minutes at 1000 F will buy precious time in the event of a fire Steel Wheel The wheel is a standard duty all welded wheel standard duty and high pressure belt drive The blades are cur...

Page 13: ...ally the Green Plus can accept 0 10V input to tie to building management systems not only allowing for savings in direct fan energy consumption but reducing the exhaust of conditioned air during off p...

Page 14: ...erter rated motors suitable for use with variable frequency drives can be supplied for belt drive models Contact your local PennBarry representative for availability Available Lek Trol Speed Controls...

Page 15: ...1 8 18 1 2 11 1 2 16 7 8 24 16 Gauge 0 064 0 050 32 42 lbs 1 FX13 25 1 2 16 1 2 18 1 2 11 1 2 17 7 8 24 16 Gauge 0 064 0 050 45lbs 2 FX16 30 1 4 22 3 8 20 1 2 16 24 24 1 4 16 Gauge 0 064 0 064 69lbs 3...

Page 16: ...44 1 2 5 1 2 470 6 All dimensions are in inches 1 Add 8 lbs for Heat and Smoke option 2 Add 11 lbs for Heat and Smoke option 3 Add 20 lbs for Heat and Smoke option 4 Add 55 lbs for Heat and Smoke opt...

Page 17: ...20 00 20 25 00 25 X Special Motors and Drives F Factory mounted L Less motor less drive M Less motor with drive Motor Enclosure 0 None 1 TE w Overload 2 TE w o Overload 3 ODP w Overload 4 ODP w o Over...

Page 18: ...al 0 None A Galvanized pedestal B Galvanized vented pedestal C Aluminum pedestal D Aluminum vented pedestal Spare Belt s 0 None 1 1 spare set 2 2 spare set Special Applications 0 None 2 Restaurant exh...

Page 19: ...Exhaust fans Outdoor units Indoor units PENNBARRY PRODUCT SOLUTIONS PennBarry www pennbarry com pennbarrysales pennbarry com Tel 972 212 4700 Fax 972 212 4702 PennBarry reserves the right to make cha...

Reviews: