Unpacking
Place carton in an upright position and
remove staples or use a sharp (knife
edge) tool to CAREFULLY cut or scribe
the sealing tape on both sides at the top
of the carton. Open carton flaps. Remove
any cardboard and wooden filler pieces,
as well as loose components or acces-
sories shipped with the unit.
Carefully remove the unit from the carton.
Inspect the unit for any damage that may
have occurred during transit and check
for loose, missing or damaged parts.
Installation
WARNING
To reduce the risk of fire, electrical
shock, or injury to persons, observe
the following:
1. Use this unit only in the matter
intended by the manufacturer. If you
have questions, contact the manu-
facturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit,
switch power off at service panel
and lock service panel to prevent
power from being switched
on accidentally.
3. Installation work and electrical
wiring must be done by a qualified
person(s) in accordance with all
applicable codes and standards,
including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent back-
drafting. Follow the heating equip-
ment manufacturer’s guideline and
safety standards such as those pub-
lished by the National Fire
Protection Association (NFPA), and
the American Society for Heating,
Refrigeration and Air Conditioning
Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall
or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always
be vented to the outdoors.
7. If this unit is to be installed over a
tub or shower, it must be marked as
appropriate for the application.
8. Never place a switch where it can
be reached from a tub or shower.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do
not use to exhaust hazardous or
explosive materials and vapors.
2. This product is designed for ceiling
installation only. DO NOT MOUNT
THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and
noisy and/or unbalanced impellers,
keep drywall spray, construction
dust. etc. off power unit.
4. Please read specification label on
product for further information and
requirements.Installation
MOUNTING OPTIONS
Figure 1
1. Housing can be installed anywhere
between joists using 2" X 4" sup-
port(s) as shown.
Figure 2
2. Housing can be installed in a sus-
pended ceiling using wire as shown.
Operation & Maintenance Manual
Printed in the USA Jan 2005
PART #99042905
Receiving and Handling
PennBarry fans are carefully inspected before leaving the factory. When the unit is
received, inspect the carton for any signs of tampering. Inspect the unit for any dam-
age that may have occurred during transit and check for loose, missing or damaged
parts. Mishandled units can void the warranty provisions. PennBarry is not responsi-
ble for damages incurred during shipment. Avoid severe jarring and/or dropping.
Handle units with care to prevent damage to components or special finishes.
Storage
Long-term storage requires special attention. Units should be stored on a level,
solid surface, preferably indoors. If outside storage is necessary, protect the
units against moisture and dirt by encasing the cartons in plastic or some similar
weatherproof material.
Zephyr Heavy Duty Combination Fan/Light
Ventilating Fan Models ZL1 & ZL2
Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
PLEASE READ AND SAVE THESE INSTRUCTIONS.