MODELS   ZQ105 • ZQ155

ZQ205 • ZQ255 • ZQ305  

Page 2

TM

TYPICAL INSTALLATION

MOUNTING 

(New Frame Construction)

CEILING JOIST

(16” centers shown)

ROUND DUCT*

GRILLE

(Install after

ceiling is

finished.)

Factory-shipped unit installed in new construction.

MOUNTING

SCREW

GRILLE

SCREW

Blower factory-shipped

in horizontal

discharge position.

Mounting brackets 

factory-shipped in 

position for ½” ceil-

ing material.

ADDITIONAL

1½” FRAMING

MOUNTING 

(Existing Frame Construction)

Factory-shipped unit installed in existing construction.

TYPICAL INSTALLATION

WIRING

WIRING

PLATE

WHITE

TO

WHITE

BLACK

TO

BLACK

TOP / BACK

OF HOUSING

120 VAC LINE IN

GROUND TO

WIRING PLATE

ROUND DUCT*

GRILLE

SCREW

FINISHED

CEILING

MATERIAL

GRILLE

(Polymeric shown)

CEILING JOIST

(16” centers

shown)

2 X 4 FRAMING

(wide side down)

MOUNTING

BRACKETS

(Attached to

opposite sides

of housing & up-

side-down,

so housing is

flush with

finished ceiling)

DUCTING 

(Horizontal blower discharge)

Two ways to connect ductwork to a factory-shipped unit.

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

ROOF CAP

ROUND

ELBOW*

ROUND

DUCT*

WALL

CAP

IMPORTANT:

Remove shipping tape from damper

Remove the shipping tape from the damper flap and make sure that 

damper flap opens and closes freely inside the ductwork. Use duct 

tape to make ductwork connections secure and air-tight.

Remove shipping ring from blower inlet

Remove the shipping ring from the blower inlet before operating 

the ventilator.

* ZQ105 & ZQ155 use 6” round duct.

  ZQ205, ZQ255 & ZQ305 use 8” round duct.

* ZQ105 & ZQ155 use 6” round duct.

  ZQ205, ZQ255 & ZQ305 use 8” round duct.

Summary of Contents for ZQ105

Page 1: ...do not damage elec trical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place a switch where it can be reached fro...

Page 2: ...olymeric shown CEILING JOIST 16 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing up side down so housing is flush with finished ceiling DUCTING Horizontal blower discharge Two ways to connect ductwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP ROUND ELBOW ROU...

Page 3: ...late mounts to side or top of housing HORIZONTAL POWER CABLE CONNECTION VERTICAL POWER CABLE CONNECTION Blower and duct connector in horizontal discharge position Factory shipped DUCT CONNECTOR Blower and duct connec tor in vertical discharge position BLOWER Change blower duct connec tor positions for vertical discharge Typical ductwork connection to a ventilator converted to vertical discharge WA...

Page 4: ...MODELS ZQ105 ZQ155 ZQ205 ZQ255 ZQ305 Page 4 TM 1103068A PennBarry 605 Shiloh Rd Plano TX 75074 972 212 4700 www pennbarry com ...

Page 5: ...7 Pour réduire le rsque d incendie utilisez seulement des donduits de ventilation en métal 8 Si cette unité doit être installée au dessus d une baignoire ou d une douche elle doit être marquée comme étant appropriée pour l application et être connectée à un circuit dérivé protége GFCI interrupteur de circuit en cas de défaut de mise à la terre du neutre 9 Ne placez jamais un interrupteur dans un e...

Page 6: ...boîtier soit au ras du plafond fini INSTALLATION DES CONDUITS décharge de soufflerie horizontale Deux manières de raccorder les conduits à un appareil prémonté Le ventilateur peut être branché depuis l extérieur du boîtier Utiliser des connecteurs homologués UL pour les branchements conformément aux codes locaux en vigueur CHAPEAU DE TOIT COUDE CIRCU LAIRE CONDUIT CIRCU LAIRE CHAPEAU DE MUR VIS DE...

Page 7: ...ale CHAPEAU DE TOIT AVERTISSEMENT Pour diminuer les risques de décharge électrique débrancher la source d alimentation avant toute opération d entretien Pour nettoyer la grille Utiliser un accessoire d aspirateur approprié ou retirer la grille et nettoyer à l aide d un chiffon doux et de savon ou de détergent doux Bien essuyer la grille avant de la réinstaller Pour nettoyer la soufflerie Retirer l...

Page 8: ...MODELS ZQ105 ZQ155 ZQ205 ZQ255 ZQ305 Page 8 TM MODÈLES 1103068A PennBarry 605 Shiloh Rd Plano TX 75074 972 212 4700 www pennbarry com ...

Reviews: