background image

Page 3

MODELS   ZQ105 • ZQ155

ZQ205 • ZQ255 • ZQ305  

TM

12¼"

9

1

/

2

"

to

10

1

/

2

"

ADUSTABLE FOR VARIOUS CEILING THICKNESSES

12¼"

1½"

to

2½"

INSTALLATION FROM ABOVE FINISHED CEILING

MOUNTING OPTIONS

WIRING OPTIONS

DUCTING OPTIONS

12¼"

1

1

/

8

"

MAX.

ADUSTABLE FOR VARIOUS CEILING THICKNESSES

Mounting brackets in 

factory-shipped position. 

(Outlet parallel to joists.)

(New construction)

12¼"

10 

3

/

4

"

to

11 

3

/

4

"

INSTALLATION FROM ABOVE FINISHED CEILING

12¼"

INSTALLATION WITH DUCTWORK

RUNNING ACROSS JOISTS

¼-20 hex nuts secure mounting brackets to housing. Loosen and 

re-tighten or remove and replace nuts as necessary for desired 

mounting bracket position.

Mounting brackets flipped 

over and mounted to outlet 

sides of housing.

(Outlet parallel to joists.)

(Existing construction)

Mounting brackets mounted 

to outlet sides of housing.

(Outlet perpendicular to joists.)

(New construction)

Mounting brackets flipped 

over and mounted to top of 

sides of housing.

(Outlet parallel to joists.)

(New or existing construction)

12¼"

1

1

/

2

"

to

2

1

/

2

"

ADUSTABLE FOR VARIOUS CEILING THICKNESSES

Mounting brackets flipped 

over to give approx. 1” 

more clearance.

(Outlet parallel to joists.)

(New construction)

Mounting brackets mounted 

to top of sides of housing.

(Outlet parallel to joists.)

(New or existing construction)

BLOWER DISCHARGE POSITIONS

WIRING PLATE

POSITION

Wiring plate mounts to side or top of housing.

HORIZONTAL POWER 

CABLE CONNECTION

VERTICAL 

POWER CABLE 

CONNECTION

Blower and duct connector 

in horizontal discharge 

position. (Factory shipped)

DUCT CONNECTOR

Blower and duct connec-

tor in vertical discharge 

position.

BLOWER

Change 

blower & 

duct connec-

tor positions 

for vertical 

discharge.

Typical ductwork connection to a ventilator converted to 

vertical discharge.

WARNING: To reduce the risk of electric shock, 

disconnect from power supply before servicing.

To clean grille:

 Use appropriate vacuum attachment or remove 

grille  and clean with a soft cloth and mild soap or detergent. Dry 

grille thoroughly before reinstalling.

To clean blower assembly:

 Remove grille, unplug blower from 

housing, remove blower mounting nuts, and carefully remove blower 

from housing. Use appropriate vacuum attachment or a soft cloth and 

mild soap or detergent to clean blower discharge area and wheel. 

DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower 

assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may 

be controlled using an on/off switch or a solid-state, variable speed 

control. Follow wiring instructions packed with control, and adhere 

to all local and state codes, and the National Electrical Code.

DUCT CONNECTOR

BLOWER

DUCTING 

(Vertical blower discharge)

* ZQ105 & ZQ155 use 6” round duct.

  ZQ205, ZQ255 & ZQ305 use 8” round duct.

ROUND

DUCT*

ROOF CAP

Summary of Contents for ZQ105

Page 1: ...do not damage elec trical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place a switch where it can be reached fro...

Page 2: ...olymeric shown CEILING JOIST 16 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing up side down so housing is flush with finished ceiling DUCTING Horizontal blower discharge Two ways to connect ductwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP ROUND ELBOW ROU...

Page 3: ...late mounts to side or top of housing HORIZONTAL POWER CABLE CONNECTION VERTICAL POWER CABLE CONNECTION Blower and duct connector in horizontal discharge position Factory shipped DUCT CONNECTOR Blower and duct connec tor in vertical discharge position BLOWER Change blower duct connec tor positions for vertical discharge Typical ductwork connection to a ventilator converted to vertical discharge WA...

Page 4: ...MODELS ZQ105 ZQ155 ZQ205 ZQ255 ZQ305 Page 4 TM 1103068A PennBarry 605 Shiloh Rd Plano TX 75074 972 212 4700 www pennbarry com ...

Page 5: ...7 Pour réduire le rsque d incendie utilisez seulement des donduits de ventilation en métal 8 Si cette unité doit être installée au dessus d une baignoire ou d une douche elle doit être marquée comme étant appropriée pour l application et être connectée à un circuit dérivé protége GFCI interrupteur de circuit en cas de défaut de mise à la terre du neutre 9 Ne placez jamais un interrupteur dans un e...

Page 6: ...boîtier soit au ras du plafond fini INSTALLATION DES CONDUITS décharge de soufflerie horizontale Deux manières de raccorder les conduits à un appareil prémonté Le ventilateur peut être branché depuis l extérieur du boîtier Utiliser des connecteurs homologués UL pour les branchements conformément aux codes locaux en vigueur CHAPEAU DE TOIT COUDE CIRCU LAIRE CONDUIT CIRCU LAIRE CHAPEAU DE MUR VIS DE...

Page 7: ...ale CHAPEAU DE TOIT AVERTISSEMENT Pour diminuer les risques de décharge électrique débrancher la source d alimentation avant toute opération d entretien Pour nettoyer la grille Utiliser un accessoire d aspirateur approprié ou retirer la grille et nettoyer à l aide d un chiffon doux et de savon ou de détergent doux Bien essuyer la grille avant de la réinstaller Pour nettoyer la soufflerie Retirer l...

Page 8: ...MODELS ZQ105 ZQ155 ZQ205 ZQ255 ZQ305 Page 8 TM MODÈLES 1103068A PennBarry 605 Shiloh Rd Plano TX 75074 972 212 4700 www pennbarry com ...

Reviews: