Mixing Valve Adjustment
To Adjust the High Temperature Limit:
1.
Remove the temperature knob screw using a 3 mm hexagonal wrench (supplied). Remove the
temperature knob.
2.
Pull off the white polymer hub which may inadvertently remain attached to the inside of the
temperature control handle. This is a “push fit” and can be “levered” out using a thin blade
screwdriver or pliers.
3.
Rotate the spindle until required maximum blend temperature is obtained at outlet point (clockwise
= decrease temperature, counterclockwise = increase temperature). When resistance is felt does not
use force to turn any further, as this can damage the internal parts.
4.
Once the desired maximum blend temperature is achieved, re-fit the hub without disturbing the
spindle: Position the hub so that the hub stop comes up against the cartridge stop preventing any
further rotation in a counterclockwise direction. Check that blend temperature has not altered.
5.
Refit the temperature knob. Make sure that the indicator points to 9 o’clock.
Summary of Contents for 360020-1EP