Mixing Valve Adjustment Rada 222
(Currently applicable only in Minnesota)
1.
Remove the handle screw, temperature handle cap, temperature handle, and indicator trim
using 3mm hex key.
2.
Pull off the temperature hub.
3.
Using the temperature hub, rotate the spindle until required maximum blend temperature is
obtained at discharge point (clockwise = decrease temperature). If resistance is felt
,
do not use
force to turn any further, as this can damage the internal parts.
4.
Once the desired maximum temperature is set, position the hub such that the lug is against the
side of the stop on the cartridge face, thus preventing counter-clockwise rotation past the stop.
5.
Check that the max temperature has not been altered.
6.
Refit the indicator trim, handle, and cap so that the indicator on the metal knob is aligned to the
left of the red markings (approximately in the 9 O'clock position), then secure with the handle
screw and a 3 mm hex key.
350151MN Rada Cartridge 222
Summary of Contents for 360020-1EP