Location of the filter
Pennington Aquagarden UV Filter should be located on a firm and level base on the ground,
at least 4’ from the pond. The filter can be buried up to the bottom rim of the head unit, leaving
just the UVC access, inlets & outlets, and cleaning handle exposed about the ground level.
Ensure the filter outlet is at no more than a maximum of 13ft head height above the lid of the filter.
INSTALLATION
WARNING:
Ballast must be affixed
vertically to a secure surface, 1 ft
minimum above the ground. Install in a
well ventilated area. Affix with the two
screws and wall plugs provided. Do not
restrict ventilation to the heat sink. IP56
weatherproof enclosure, do not submerge.
Caution hot surface, turn off power and
allow to cool before removal. Do not run
the UV filter for prolonged periods without
water flow from a pump to cool the UVC
assembly and quartz sleeve.
UVC Ballast installation
HOSE
PUMP
(sold separately)
WATERFALL
CLEAN WATER RETURNED DIRECT
TO POND OR VIA WATERFALL
WASTE & DIRT RELEASED
TO THE GARDEN
(ONLY WHEN CLEANING)
AWESOME
POND
MACHINE
Important:
This appliance can be used by children aged 8 and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning the use of the appliance in a safe way
and understand the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
7
3x multi hose tails, (inlet,
outlet & waste) to fit the
following hose diameters:
•
1½”
•
1¼”
•
1”
•
¾”
x1 waste blanking cap and X-ring
ACCESSORIES SUPPLIED
1ft (min)
Secure
surface
Electrical installation