Follow these guidelines for installation:
1.  Provide properly sized sump (see Specifications).
2.  do not set pump directly on the bottom of sump pit 

if it is not solid. raise the pump by using bricks or 
concrete blocks underneath it.

3.  make sure sump is free of string, cloth, nails, gravel, 

etc. before installing pump.

4.  do not remove ground pin from electrical plug.
5.  do not use an extension cord to operate this pump.
6.  For proper automatic operation, make sure the pump 

power cord is plugged into the piggyback receptacle 
on the switch cord. Three phase models must be 
properly connected to a suitable control panel.

 

do not cut, crimp, or bend single phase switch 
power cord (15). The vent tube needs to “breathe” 
for proper operation of switch. This may cause pump 
failure and void warranty.

7.  Use steel or plastic pipe for all connecting lines 

between pump and sewer outlet.

 NOTICE: Some city regulations do not 

allow installing a pump with plastic pipe. 
check local regulations.

8.  Use PTFE pipe thread sealant tape on pipe 

connections. do not use ordinary pipe joint 
compound on plastic pipe or pump. Pipe joint 
compound can attack plastics and damage pump.

9.  In applications where the pump may sit idle for 

months at a time, it is recommended that the 
pump(s) be cycled every month to ensure the 
pumping system is working properly when needed.

10. a check valve should be installed horizontally in 

discharge pipe.

11. The optional Hydromatic Q alert is an audible 

alarm system for high water conditions. It should be 
installed in every sump for greater protection.

 

NOTICE: Q alert is for indoor use only. other Q 
alarm and control panels are available for outdoor 
use. contact your HYdromaTIc distributor 
for applications.

12. Use pump partially or completely submerged for 

pumping waterlike liquids. The pump will pump 
solid materials up to 2” (spherical) in diameter.

 

 Risk of fire. do not pump flammable 

liquids. Strong chemicals or salt water should not 
be pumped without consulting your HYdromaTIc 
distributor for proper seals and coatings.

Operation

NOTICE: do not allow pump to run in a dry sump. 
doing so will void the warranty and may damage 
the pump.
an automatic overload protector in the motor will 
protect the motor from burning out due to overheating/
overloading. When the motor cools down, the overload 
protector will automatically reset.
If overload trips frequently, check for the cause. It could 
be a stuck impeller, wrong/low voltage, or electrical 
failure in motor. If an electrical failure in the motor is 
suspected, have it serviced by a competent repairman.

Maintenance

read the following instructions carefully before replacing 
any parts. reasonable care and safe methods should be 
practiced. check local codes and requirements before 
installation. only a competent plumber/electrician 
should make the installations.
Submerge pump in a disinfectant solution (dilute chlorine 
bleach) for at least one hour before disassembling pump.
check for an obstruction in the impeller by looking 
through the suction hole of the pump. The shaft should 
turn freely if unobstructed. Keep fingers, clothing or any 
material from suction inlet.

The steps described in this section should be performed 
only by an authorized service center.

NOTICE: read all directions before replacing any 
parts. remove pump and switch from power source 
before servicing.
The numbers in parentheses, such as "(3)" or "(16)", refer 
to item numbers used on the Repair Parts diagram.

Replacing diaphragm switch

From switch housing (15) remove screw (14) from 
housing. replace with new switch. Insert screw (14) into 
housing (15) and tighten. Plug pump power cord into 
the piggyback receptacle on the switch cord, and then 
switch plug into correct power source.

Checking motor operation

Plug power cord directly in power source to check motor 
operation. motor should start and run smoothly. If motor 
does not start, pump must be dismantled and motor 
checked. Be certain to unplug cord before disconnecting 
any wires.

Summary of Contents for HYDROMATIC SK60 Series

Page 1: ...èces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 888 957 8677 Français Pages 11 20 INSTALLATION AND OPERATOR S MANUAL SK60 Submersible Sewage Ejector Pump Installation et manuel de l opérateur Pompe submersible d eaux d egout SK60 269 Trillium Drive Kitchener Ontario Canada N2G 4W5 PH 519 896 2163 293 WRIGHT STREET DELAVAN WI 53115 WWW hydromati...

Page 2: ...sewage pump or a high water alarm See Troubleshooting in this manual for information about common sewage pump problems and remedies For more information see your retailer call Hydromatic customer service at 1 888 957 8677 or visit our web site at hydromatic com Hazardous voltage risk of electrical shock Shock can cause serious injury or death Failure to follow the warnings below can result in fata...

Page 3: ...ntenance as required 14 Drain all the liquid from the system before servicing California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm Installation Thank you for purchasing this HYDROMATIC pump To help ensure years of trouble free operation please read the manual carefully Befo...

Page 4: ...sk of fire Do not pump flammable liquids Strong chemicals or salt water should not be pumped without consulting your Hydromatic distributor for proper seals and coatings Operation NOTICE Do not allow pump to run in a dry sump Doing so will void the warranty and may damage the pump An automatic overload protector in the motor will protect the motor from burning out due to overheating overloading Wh...

Page 5: ... in motor seal should be replaced Replacing seal Hold rotor On 3 phase motors only remove the impeller screw and impeller washer Unscrew impeller 13 Tap on end of shaft with plastic or rubber hammer This will push the rotating seal 10 from shaft and also push lower bearing from seal plate Clean seal plate 11 and motor housing 19 thoroughly All sand and dirt must be removed Remove stationary cerami...

Page 6: ... air lock use a small screwdriver to clear hole in the impeller cavity As a secondary precaution in installations of this type an 1 8 hole should be drilled in the discharge pipe just above the volute The check valve should be at least 12 inches above pump discharge and mounted horizontally Do not put check valve directly into pump discharge opening NOTICE In sumps where the pump is operating dail...

Page 7: ... hole in the discharge pipe between the pump discharge and the check valve Flow in matches or exceeds the pump s capacity A larger pump or more pumps may be needed Little or no effluent delivered from pump Check valve plugged stuck shut or installed backwards Make sure check valve is installed correctly flow arrow should point away from pump and functioning correctly System head excessive Consult ...

Page 8: ... 2 19103A043 9 Gasket 1 003240011 Ref Description Qty Part Number 10 Shaft Seal 1 014525A010 11 Seal Plate 1 068460002 12 Volute 1 068180002 13 Impeller 1 047810002 14 Screw 1 000300211 15 Diaphragm Switch 115V 20 STD 1 149740225 Diaphragm Switch 230V 20 STD 1 149740235 16 Switch Bracket 1 055020051 17 Capscrew 3 001010101 18 O Ring 1 000770031 19 Motor Housing 1 000565002 20 Handle 1 000600005 21...

Page 9: ...rvice will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE LIABLE FOR ...

Page 10: ... 1750 RPM three phase 6 10 HP polyphase 1750 RPM Intermittent Liquid Temperature 140 F 60 C Minimum Recommended Sump Diameter Simplex 24 609 6 mm Duplex 36 914 4 mm Automatic Operation Diaphragm pressure switch single phase only manual available Materials of Construction Class 30 cast iron Impeller Class 30 cast iron two vane nonclog Discharge Size 2 NPT 50 8 mm 3 NPT 76 2 mm optional Solids Handl...

Page 11: ...se d une pompe de puisard secondaire d une pompe de puisard de secours fonctionnant sur le courant continu et ou d une alarme de niveau haut d eau Se reporter au Tableau de recherche des pannes de cette Notice pour tout renseignement concernant les problèmes courants des pompes de puisard et comment y remédier Pour plus de renseignements s adresser au marchand de chez qui on a acheté la pompe ou a...

Page 12: ...s et bien éclairée enlever tous les outils et tout le matériel dont on ne se sert pas 9 Ne pas laisser les visiteurs s approcher de la zone de travail 10 Empêcher les enfants d accéder à l atelier en posant des cadenas un disjoncteur général et en enlevant les clés des démarreurs 11 Dissiper toute la pression du système avant d intervenir sur un élément 12 Si la conduite de refoulement de la pompe...

Page 13: ...rtiellement ou complètement immergée pour le pompage de liquides comme l eau La pompe prend en charge les corps solides sphériques jusqu à 5 cm de diamètre Cette pompe n a pas été vérifiée pour une utilisation en piscine Risque d inflammable Ne pompez pas de liquides inflammables Ne pompez pas de produits chimiques agressifs ou d eau salée sans avoir consulté votre distributeur Hydromatic concerna...

Page 14: ...tre changées AVIS Lorsque vous changez d échelle remettez toujours l appareil de mesure à zéro 0 avant d effectuer une mesure Si le fil est bon l aiguille de l ohmmètre s approche de zéro et ne bouge plus Si l aiguille de l ohmmètre ne bouge pas du tout le fil est coupé et doit être réparé ou remplacé Raccordez un des fils de l ohmmètre à un des fils du stator et à l aide de l autre fil de l ohmmè...

Page 15: ... la volute 12 avec des boulons 17 6 Avant de remplir le carter du moteur avec de l huile effectuez un test d étanchéité des joints Appliquez une pression d air de 3 à 3 5 kg au niveau du robinet à filetage NPT de 1 4 po 21 situé sur le dessus du couvercle du moteur et fermez le boîtier AVIS Une pression trop élevée endommagera le joint Le joint devrait alors être remplacé Plongez ensuite la pompe ...

Page 16: ...ème fonctionne librement La pompe est bloquée par de l air Arrêtez la pompe pendant une minute environ puis redémarrez la Répétez l arrêt et le démarrage jusqu à ce que le blocage par l air soit éliminé Si le blocage persiste COUPEZ L ALIMENTATION ÉLECTRIQUE tirez sur la pompe et percez un trou de 1 8 po 0 3 cm dans la conduite de refoulement entre le refoulement de la pompe et le clapet antiretou...

Page 17: ...103A052 Vis refoulement de 3 po 2 19103A043 9 Joint 1 003240011 Ref Description Qte Numéro de pièce 10 Joint d arbre 1 014525A010 11 Plaque d étanchéité 1 068460002 12 Carter de la volute 1 068180002 13 Impulseur 1 047810002 14 Vis 1 000300211 15 Interrupteur à membrane 115V 20 pi 1 149740225 Interrupteur à membrane 230V 20 pi 1 149740235 16 Support d interrupteur 1 055020051 17 Vis 3 001010101 18...

Page 18: ...Aucune demande de service en vertu de sa garantie ne sera acceptée après expiration de la durée de sa garantie Ces garanties ne sont pas transférables EXCEPTIONS Les pompes pour applications spéciales les pompes de puisard de secours à batterie les pompes d effluents à filtre les pompes broyeuses et les pompes d eaux d égout de 2 1 2 po Hydromatic sont garanties pendant une période de 12 mois suiv...

Page 19: ...in Température de liquide intermittente 140 F 60 C Diamètre de fosse minimal recommandé Simplex 24 po 609 6 mm Duplex 36 po 914 4 mm Fonctionnement automatique Pressostat à membrane une seule phase d emploi disponibles Matériaux de construction Fonte de classe 30 Impulseur Fonte de classe 30 deux palettes Dimension du refoulement 2 po NPT 50 8 mm 3 po NPT 76 2 mm opt Gestion des matières solides 2...

Page 20: ......

Reviews: