11.
INSTALL UNI-TENSION CLAMP:
With the hook ends of the circular uni-tension
clamp pointing down, spread the clamp and place it in the “U” recesses of the
locking levers. Be sure the hook ends of the clamp are located between the pair
of locking levers as shown below and that the wire clamp is properly engaged
with all of the lock levers.
12. Place a cloth on the ground to protect the lens. Turn the light over so the lens is
resting on the cloth. Be sure the orientation of the wire clamp and the bolt
connection is positioned at 45°. Tighten the bolt and nut until the distance
between the ends of the clamp equals ¼-in or less.
13.
PROCEED TO “Replacing the IntelliBrite White Spa Light Assembly (in
an existing pool or spa)” on page 3 for spa light assembly installation
instructions.
Tighten nut and bolt about 90˚ from
the Pilot Screw between the lock levers.
Orientation of bolt and wire clamp
20
Screw
Bolt
(and Hook ends)
Uni-tension
wire clamp
Lock lever
(x4)
Pilot screw
Lens
Gasket
Face ring
IntelliBrite
Spa light
assembly
Nut (Pilot screw)