IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
IntelliChlor Plumbing Diagram
Plumbing the IntelliChlor Electronic Chlorine Generator (IECG):
•
Always install the IntelliChlor Electronic Chlorine Generator AFTER the filter and heater (see
“System Diagram” on page 4). The ICEG should be no closer than three (3) feet away from the
heater outlet.
•
If the IECG is installed on a pool/spa combination system, install (see diagram below) the IECG
BEFORE the pool/spa return valve to allow proper chlorination of both the pool and spa and also to
avoid creating gas traps in the pipes.
Loop Plumbing Diagram
The IntelliChlor Electronic Chlorine Generator is designed to operate with water flow rates from 25 gallons per
minute (gpm) up to 105 gpm. Do not exceed 105 gpm or pipe manufacturers recommended flow rate,
whichever is less. For flow rates over 80 gpm, it is recommend that you use a bypass loop (as shown below)
for best chlorine production. Installations with flow rates over 80 gallons per minute are those that have
in-floor cleaning systems or booster pumps. These systems MUST use a bypass loop with the IECG with a
flow control valve that assures that the flow through the IECG is maintained within its designed operating
water flow rates.
Flow control valve
Bypass loop
NOT TO SCALE
NOT TO SCALE
Note:
For best flow
sensing, provide at
least 12"-18" of straight
pipe in front of the cell
inlet.
Summary of Contents for IntelliChlor IC60
Page 12: ...6 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 38: ...32 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...