29
IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
Wiring AC Power from IntelliChlor (SCG) and IntelliFlo pump to
IntelliTouch, EasyTouch and SunTouch Automation Control System
To connect AC power to the IntelliChlor
Power Center:
1. Unlatch the load center/power center enclosure door spring latche(s), and open the door.
2.
EasyTouch/IntelliTouch:
Loosen the two (2) retaining screws from the control panel.
(a)
Lower down the control panel on its hinges to access the motherboard located behind the control
panel.
(b)
Route the four conductor cable up through the low voltage raceway in the load center to the
motherboard.
SunTouch:
Route the four conductor cable up through the lower grommet opening up to the main
filter pump relay.
3. Strip back the cable conductors ¼ in. Insert the wires into the connector screw terminals (provided
in the kit). Secure the wires with the screws. Make sure to match the color coding of the wires;
Red = +15, Yellow = +DT, Green = -DT, and GND = Black.
4. Insert the connector screw terminal onto the
COM Port
pins on the circuit board:
(EasyTouch
J20, IntelliTouch J7/8, SunTouch J11)
.
7. When the connection is completed:
EasyTouch/IntelliTouch:
Close the control panel and secure it
with the two (2) retaining screws.
SunTouch:
Close the front control panel and secure with the
retaining screw.
8. Close the load center front door. Fasten the spring latche(s).
IntelliChlor (SCG) AC Wiring Instructions: When using the IntelliChlor salt chlorine generator and an
IntelliFlo pump (or 2-speed pump) with a Pentair Water Pool and Spa
®
IntelliTouch®, EasyTouch® or
SunTouch® automation control system , the IntelliChlor AC power center wires must be connected to the
PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see page 31 for diagram).
This ensures that the IntelliChlor cell produces chlorine only when the main filter pump is on. This method
does not require a ground fault circuit-interrupter (GFCI) to protect the circuit. Note: For non-automation
systems using a time clock, see page 35 for wiring information.
BLK
GRN
YEL
RED
Personality board
(Connector J7 or J8)
COM ports
IntelliTouch Personality Circuit Board
Indoor Control Panel
IntelliChlor
IntelliFlo
RF Transceiver
COM PORT
(J20)
EasyTouch Circuit Board
9.
WARNING
- Switch OFF main system power to the Load Center before making any connections.
Summary of Contents for IntelliChlor IC60
Page 12: ...6 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...