Rev. A 2-4-2000
P/N 471438
Installation Section
MiniMax 100 Electronic Direct Spark Ignition Wiring Diagram
THERMAL
FUSE
HI LIMIT SW.
PRESSURE SW.
WATER
THERMOSTAT
ON/OFF SW.
IGNITER
SPARK
MODULE
GAS VALVE
MiniMax CE100 ELECTRONIC WIRING DIAGRAM
OR SUPERCEDING LOCAL WIRING CODES.
INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO ALL NATIONAL
WIRE, 18 GAUGE, 600V, 150˚ C TEMPERATURE RATING..
THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED
UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 150˚ C TEMPERATURE RATING.
IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY
TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE
GROUND SCREW WITH PAINT CUTTING WASHER
EXTERNAL
BOND LUG
CHASSIS
SHEET METAL
V1
TH
V2/GRD
N
H
GRN
WHT
BLUE
WHT
ORN
ORN
GRN
WHT
WHT
WHT
WHT
WHT
WHT
ELECTRONIC
BLK
ORN
BLUE
YELLOW
MiniMax 100 Millivolt Wiring Diagram
External Controls
Any external control (such as a
time clock) should be connected to
the electrical supply to the
appliance and must not interrupt or
disturb the internal wiring of the
appliance.
12