P/N 471438
Rev. A 2-4-2000
WATER CONNECTIONS
QUICK-FLANGE II INSTALLATION INSTRUCTIONS
FOR 1½ SCHEDULE 40 CPVC or ABS PIPE or SCHEDULE 80 PVC
(you may adapt to SCH 40 PVC 12 inches beyond the Quick Flange II)
(1½ in. npt x 1½ in. CPVC/ABS slip Male Adaptor may be required)
Figure 13.
Installation Section
15
1.
Insert 2 in. rubber gaskets over 2 in. gasket retainer rings molded to bottom of
Quick-Flange II; see Figure 13.
2.
Bolt Quick-Flange II to header using supplied 3/8 in. bolts and 3/8 in. washers.
3.
Using pipe dope, thread pipe directly to Quick-Flange II.
a. Or, first thread a 1½ in. npt x 1½ in. slip CPVC/ABS male adaptor (not
supplied) to the Quick-Flange II, and after preparing the joint by sanding with a
medium grit sandpaper, glue the pipe to the adaptor with a quality solvent glue.
NOTE
All versions of the Minimax 100 include a Quick-Flange II Adaptor.
Each MiniMax 100 Quick-Flange II Accessory Kit, p/n 471083,
contains the following items:
One (1) Quick-Flange II unit
Two (2) 2 in. Rubber Gaskets
Four (4) 3/8 in. Bolts
Four (4) 3/8 in. Washers