CLEAN AND CLEAR
®
PLUS Cartridge Filter Installation and User’s Guide
2
If doubt exists as to the pressure to which the system will be subjected, install an ASME
approved automatic Pressure Relief or Pressure Regulator in the circulation system for the
lowest working pressure of any of the components in the system.
SECTION II. FILTER OPERATION AND CLEANING
A. GENERAL INFORMATION
1. This filter operates under pressure. When clamped properly and operated without air in the
circulating system, this filter will operate in a safe manner.
2. The maximum working pressure of this filter is 50 p.s.i. Never subject this filter to pressure in
excess of this amount - even when conducting hydrostatic pressure tests.
When performing hydrostatic pressure tests or when testing for external leaks of the
completed filtration and plumbing system, insure that the MAXIMUM PRESSURE
that the
filtration system will be subjected to DOES NOT EXCEED THE MAXIMUM WORKING
PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM.
In most cases, the maximum pressure will be stated on each component of the system.
If doubt exists as to the pressure to which the system will be subjected, install an ASME
approved automatic Pressure Relief or Pressure Regulator in the circulation system for the
lowest working pressure of any of the components in the system.
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE
CIRCULATING SYSTEM (e.g., FILTER LID, PUMP, FILTER, VALVES, ETC.) IS SERVICED,
AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR
CAN CAUSE THE LID TO SEPARATE FROM THE TANK BOTTOM WHICH CAN RESULT
IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL
HAZARD, FOLLOW THESE INSTRUCTIONS.
1. BEFORE REPOSITIONING VALVES AND BEFORE BEGINNING THE ASSEMBLY,
DISASSEMBLY, OR ADJUSTMENT OF THE CLAMP OR ANY OTHER SERVICE
OF THE CIRCULATING SYSTEM: (A) TURN THE PUMP OFF AND SHUT OFF ANY
AUTOMATIC CONTROLS TO ASSURE THE SYSTEM IS NOT INADVERTENTLY
STARTED DURING THE SERVICING. (B) OPEN AIR RELIEF VALVE, AND (C) WAIT
UNTIL ALL PRESSURE IS RELIEVED - PRESSURE GAUGE MUST READ ZERO (0
psi).
2. WHENEVER INSTALLING OR REMOVING THE FILTER CLAMP, FOLLOW THE
FILTER
CLAMP INSTALLATION AND REMOVAL INSTRUCTIONS EXACTLY
.
3. ONCE SERVICE ON THE CIRCULATING SYSTEM IS COMPLETE, FOLLOW
START-
UP INSTRUCTIONS EXACTLY.
4. MAINTAIN CIRCULATION SYSTEM PROPERLY. REPLACE WORN OR DAMAGED
PARTS IMMEDIATELY (e.g., but not limited to, lid, knob, pressure gauge, clamping
assembly, relief valve, O-rings, etc.)
5. BE SURE THAT THE FILTER IS PROPERLY MOUNTED AND POSITIONED
ACCORDING TO INSTRUCTIONS PROVIDED.