background image

 

 

 

Page 8 of 10

 

 

 

 

 

NOTE

 

 

Glycerine is a commercially  available 

lubricant that will not foul elements.

 

However, silicon lubricant is 

recommended for this application.

 

 

 

 

Head Disassembly  (Contd...)

 

 

 

 

F/C Port

 

 

 

Permeate Port

 

 

 

 

 

 

 

 

 

 

Circlip

 

 

 

Locking Segment

 

 

 

O-rings

 

 

 

Sealing Plate

 

Retaining Ring

 

Removal Tool

 

 

 

 

 

Bearing Plate

 

 

 

 

 

 

 

 

 

 

Retaining Ring

 

 

 

 

 

Head Component Identification  (40E100) - Head Disassembled

 

 

 

Head Assembly

 

1.   Use only head components in as-new condition. Use 

new O-rings each time the head is assembled.

 

 

2.   Cover O-rings with a this even layer of Parker Super 

O-Lube

TM  

silicon lubricant or the lubricant recomm- 

ended by your element supplier.

 

 

 

3.   Assemble one Port Seal into the groove in the Sealing 

Plate and the other into the groove on the small end 
of the Permeate Port. Insert Adapter seal into the 
groove at the large end of the Permeate Port.

 

 

 

 

 

 

 

 

 

 

 

Lubricating  Plug seals and O-rings

 

 

Inserting Permeate Port seal

 

 

Distributed by Applied Membranes, Inc. | www.appliedmembranes.com |  (760) 727-3711 |  USA

Summary of Contents for 40E100 RO

Page 1: ...may result in catastrophic failure pressurize vessel until after visually inspecting to ensure that the spiral retaining ring is correctly installed tolerate leaks or allow end closures to be routinel...

Page 2: ...nternally wound in place Shell exterior coated with white high gloss polyurethane paint Head 2 2 47471 Bearing Plate 6061 T6 hard anodiz ed Alum Alloy 3 2 50481 Seal Plate PVC Thermoplastic gray 120 F...

Page 3: ...ng ring Use the smaller hole Hold the tool flat against the end margin and parallel to the vessel bore It is then possible to pull the end of the retaining ring straight out The retaining ring may sna...

Page 4: ...3 Once the retaining ring has been removed examine the area for burrs or dings which could damage the head or membrane If necessary use ScotchBriteTM or 600 grade sandpaper to smooth the area Removin...

Page 5: ...nd upstream end is the end plumbed most directly to the pump 2 Push element s out of vessel from the upstream end 3 For multi element vessels remove the intercon nectors and retain for reinstallation...

Page 6: ...ons to the vessel and all around the vessel itself If any leaks occur release pressure from the vessel and tighten the fittings as necessary Then pressurize vessel and check for leaks again 8 Insert e...

Page 7: ...Plug Seal 2 Remove circlip from its groove in the Permeate port Take care not to scratch the hard anodized surface of the bearing plate Separate the Sealing plate and the Bearing plate 5 Push Feed Co...

Page 8: ...Use only head components in as new condition Use new O rings each time the head is assembled 2 Cover O rings with a this even layer of Parker Super O LubeTM silicon lubricant or the lubricant recomm e...

Page 9: ...to the machined end of the Feed Concentrate Port so that the two pairs of holes line up 7 Assemble the Permeate Port through the center hole in the Sealing Plate align the Permeate port pin with the S...

Page 10: ...etal parts using a wire brush 2 Scrub the entire surface with medium grade Scotch BriteTM until all contaminants are removed 3 Rinse parts clean with fresh water and dry 4 Inspect all parts for servic...