Page 8 of 10
NOTE
Glycerine is a commercially available
lubricant that will not foul elements.
However, silicon lubricant is
recommended for this application.
Head Disassembly (Contd...)
F/C Port
Permeate Port
Circlip
Locking Segment
O-rings
Sealing Plate
Retaining Ring
Removal Tool
Bearing Plate
Retaining Ring
Head Component Identification (40E100) - Head Disassembled
Head Assembly
1. Use only head components in as-new condition. Use
new O-rings each time the head is assembled.
2. Cover O-rings with a this even layer of Parker Super
O-Lube
TM
silicon lubricant or the lubricant recomm-
ended by your element supplier.
3. Assemble one Port Seal into the groove in the Sealing
Plate and the other into the groove on the small end
of the Permeate Port. Insert Adapter seal into the
groove at the large end of the Permeate Port.
Lubricating Plug seals and O-rings
Inserting Permeate Port seal