Installer Manual Performa 263-268 / LOGIX 740-760 - Installation
Ref. MKT-IM-011 / A - 15.06.2017
21 / 64
4.5. Salt
amount
definition
3 salt settings are available on 740 and 760 controls:
5.
Installation
5.1.
Safety notices for installation
•
Observe all warnings that appear in this manual.
•
Only qualified and professional personnel are authorized to carry out installation work.
5.2. Installation
environment
5.2.1. General
•
Use only brine salts designed for water softening. Do not use ice melt salt, block, or rock salts.
•
Keep the media tank in the upright position. Do not turn on its side, upside down, or drop.
Turning the tank upside down may cause media to enter the valve or might plug the upper
screen.
•
Follow State and local codes for water testing. Do not use water that is micro-biologically unsafe
or of unknown quality.
•
When filling media tank, first place the control valve in backwash position, then do not open
water valve completely. Fill tank slowly to prevent media from exiting the tank.
•
When installing the water connection (bypass or manifold) connect to the plumbing system first.
Allow heated parts to cool and cemented parts to set before installing any plastic parts. Do not
get primer or solvent on O-rings, nuts, or the valve.
Settings
Amount of brine used
Equivalent CaCO
3
L - (Low Salt)
40 [g
salt
/L
resin
]
30 [g/L]
S - (Standard Salt)
120 [g
salt
/L
resin
]
60.2 [g/L]
H - (High Salt)
200 [g
salt
/L
resin
]
75.2 [g/L]