Installer Manual Performa 263-268 / LOGIX 740-760 - Maintenance
Ref. MKT-IM-011 / A - 15.06.2017
45 / 64
9.2.2. Cleaning the injector valve
9.2.3. Cleaning the refill controller
No.
Operation
A
Using a Torx key, unscrew and remove the injector cap (
4
).
Caution
Take care not to damage the injector (
5
).
B
Using pliers, gently extract the injector (
5
) from valve body.
C
Clean the injector (
5
) using compressed air, a soft brush or possibly a pin.
D
Reverse above procedure steps to rebuild.
No.
Operation
A
Using a Torx key, unscrew and extract the refill controller (
3
).
B
Clean the refill controller (
3
) with a soft brush.
Make sure the refill controller groove is perfectly clean.
C
Check for O-rings integrity.
D
Check for ball (
2
) integrity (if present).
E
Clean the refill controller chamber (
1
) before reinserting the refill controller (
3
).
F
Reverse above procedure steps to rebuild.
A