TABLE OF CONTENTS
MANUAL OVERVIEW ................................................................ 2
SAFETY INFORMATION ............................................................ 2
TYPICAL TOOLS AND FITTINGS REQUIRED ............................ 3
VALVE DIMENSIONS ................................................................ 3
VALVE LAYOUT ......................................................................... 4
SPECIFICATIONS ..................................................................... 4
EQUIPMENT INSTALLATION .................................................... 4
SYSTEM STARTUP .................................................................... 6
INSTALLATION CHECKLIST ..................................................... 6
CONTROL OPERATION AND LAYOUT ...................................... 6
PROGRAMMING THE 606F DEMAND CONTROL ..................... 7
REMOTE REGENERATION ....................................................... 8
VALVE ASSEMBLY .................................................................... 9
TROUBLESHOOTING ................................................................ 10
FLOW DIAGRAMS ..................................................................... 11
FLOW PERFORMANCE DATA CHARTS .................................... 12
MANUAL OVERVIEW
How To Use This Manual
This manual is designed to guide the installer through the
process of installing and starting the filter.
This manual is a reference and will not include every system
installation situation. The person installing this equipment
should have:
• Knowledge in water filter installation
• Basic plumbing skills
Icons That Appear In This Manual
WARNING:
Failure to follow this instruction can result in
personal injury or damage to the equipment.
NOTE: This will make the process easier if followed.
Inspection
Inspect the unit for damage or missing parts.
SAFETY INFORMATION
Electrical
• There are no user-serviceable parts in the AC adapter,
motor, or controller. In the event of a failure, these should
be replaced.
• All electrical connections must be completed according to
local codes.
• Use only the power AC adapter that is supplied.
• The power outlet must be grounded and always on.
• To disconnect power, unplug the AC adapter from its
power source.
• Install an appropriate grounding strap across the inlet
and outlet piping of the water system to ensure proper
grounding is maintained.
Mechanical
• Do not use petroleum-based lubricants such as
petroleum jelly, oils, or hydrocarbon-based lubricants.
Use only 100% silicone lubricants.
• All plastic connections should be hand tightened.
Plumber tape should be used on connections that do not
use an O-ring seal. Do not use pliers or pipe wrenches.
• All plumbing must be completed according to local codes.
• Soldering of the plumbing should be done before
connecting to the valve. Excessive heat will cause interior
damage to the valve.
• Observe local drain line requirements.
• Do not use lead-based solder for sweat solder
connections.
• Do not support the weight of the system on the control
valve fittings, plumbing, or the bypass.
• It is not recommended to use sealants on the threads.
Use plumber tape (PTFE) on all threads.
General
• Observe all warnings that appear in this manual.
• This system is not intended to be used for treating water
that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
• Keep the unit in the upright position. Do not turn on side,
upside down, or drop. Turning the tank upside down will
cause media to enter the valve.
• Operating ambient temperature is between 34°F (1°C)
and 120°F (49°C).
• Operating water temperature is between 34°F (1°C) and
100°F (38°C).
• Working water pressure range is 20 to 125 psi
(1.38 to 8.61 bar).
• Follow state and local codes for water testing.
• When filling media tank, do not open water valve
completely. Fill tank slowly to prevent media from exiting
the tank.
• Always make modifications to house plumbing first.
Connect to valve last.
• Plastic parts and O-rings may be damaged by heat and
solvents. When constructing plumbing connections, allow
heated parts to cool and protect parts from solvents.
Location Selection
Location of a water treatment system is important. The
following conditions are required:
• Level platform or floor.
• Constant electrical supply to operate the controller.
• Total minimum pipe run to water heater of ten feet (three
meters) to prevent backup of hot water into system.
• Local drain or tub for discharge as close as possible.
• Water line connections with shutoff or bypass valves.
• Room to access equipment for maintenance.
2 •
Autotrol
®
363 Demand Automatic Filter Valve