VALVE LAYOUT
Recycle
Button
Display
Time
Button
Backwash
Duration
Button
Cleaning Cycle
Interval/Days
Button
Remove
Cover
Delayed
Cleaning Cycle
Indicator
Flow
Indicator
Figure 2
SPECIFICATIONS
Flow Rates (Valve Only)
Service @ 15 psi ....................................21 gpm (79 lpm) full flow
Backwash @ 25 psi ................................19 gpm (72 lpm) full flow
Fast Rinse @ 25 psi ...............................................5 gpm (19 lpm)
Valve Connections
Tank Thread .............................2-1/2 inches (63.5 mm) – 8, male
Inlet/Outlet Thread ..................... 3/4 inch (19.05 mm) BSP, male
..................................................... 3/4 inch (19.05 mm) NPT, male
...........................................................1 inch (22.5 mm) BSP, male
.......................................................... 1 inch (22.5 mm) NPT, male
..................................................1-1/4 inch (31.75 mm) BSP, male
..................................................1-1/4 inch (31.75 mm) NPT, male
....................................................1-1/2 inch (38.1 mm) BSP, male
....................................................1-1/2 inch (38.1 mm) NPT, male
Drain Line..........................................1 inch (22.5 mm) BSP, male
.......................................................... 1 inch (22.5 mm) NPT, male
Distributor Tube Diameter ............................ 1.050 inch (27 mm)
Distributor Tube Length ... Flush to top of tank ± 1/2 inch (13 mm)
Design Specifications
Valve Body .......................................................Glass-filled Noryl
®
Rubber Components ........................Compounded for cold water
Operating Pressure ............................. 20-125 psi (1.38–8.61 bar)
Water Temperature ..........................................34-100°F (1-38°C)
Ambient Temperature* ....................................34-120°F (1-49°C)
* Recommended for indoor use only
Drain Line Flow Controls
1" (22.5 mm) ..............................................8-20 gpm (30-76 lpm)
3/4" (1.9 cm) ................................................4-7 gpm (15-29 lpm)
EQUIPMENT INSTALLATION
If you are also installing a water softener, the softener should
be installed downstream of this system.
Grounding the Plumbing
It is important that the plumbing system be electrically
grounded. When a water treatment system is installed a
nonmetallic bypass valve may interrupt the grounding. To
maintain continuity, a grounding strap can be purchased at a
hardware store. When it is installed the strap will connect the
plumbing into the system to the plumbing leaving the system.
Water Line and Bypass Connection
Once you have selected your location check the direction of the
water flow in the main pipe.
A bypass valve system should be installed on all water
conditioning systems. The bypass valve system isolates the
filter from the water supply and provides untreated water to
service during routine maintenance and servicing procedures.
B
1
3
2
Figure 3
Normal Operation
• Valves 1 and 3 open
• Valve 2 closed
Bypassed Position
• Valve 2 open
• Valves 1 and 3 closed
The valve connects to the water system by means of a
connector assembly. The connector is secured to the plumbing
and then inserted into the universal ports on the valve. A clip is
used to hold it in place.
Figure 4 Connector Assembly
Before inserting the connector:
• Check that all O-rings are in place and not damaged.
• O-rings are pre-lubricated. Sliding surfaces should be
lubricated with 100% silicone grease.
Drain
Inlet
Outlet