VALVE LAYOUT

Recycle 

Button

Display

Time 

Button

Backwash 

Duration

Button

Cleaning Cycle

Interval/Days 

Button

Remove 

Cover

Delayed 

Cleaning Cycle 

Indicator

Flow 

Indicator

Figure 2 

SPECIFICATIONS

Flow Rates (Valve Only)

Service @ 15 psi ....................................21 gpm (79 lpm) full flow
Backwash @ 25 psi ................................19 gpm (72 lpm) full flow
Fast Rinse @ 25 psi ...............................................5 gpm (19 lpm)

Valve Connections

Tank Thread .............................2-1/2 inches (63.5 mm) – 8, male
Inlet/Outlet Thread ..................... 3/4 inch (19.05 mm) BSP, male 

..................................................... 3/4 inch (19.05 mm) NPT, male  

...........................................................1 inch (22.5 mm) BSP, male 

.......................................................... 1 inch (22.5 mm) NPT, male 

..................................................1-1/4 inch (31.75 mm) BSP, male 

..................................................1-1/4 inch (31.75 mm) NPT, male 

....................................................1-1/2 inch (38.1 mm) BSP, male 

....................................................1-1/2 inch (38.1 mm) NPT, male
Drain Line..........................................1 inch (22.5 mm) BSP, male  

.......................................................... 1 inch (22.5 mm) NPT, male
Distributor Tube Diameter ............................  1.050 inch (27 mm)
Distributor Tube Length ... Flush to top of tank ± 1/2 inch (13 mm)

Design Specifications

Valve Body .......................................................Glass-filled Noryl

®

 

Rubber Components ........................Compounded for cold water
Operating Pressure ............................. 20-125 psi (1.38–8.61 bar)
Water Temperature ..........................................34-100°F (1-38°C)
Ambient Temperature* ....................................34-120°F (1-49°C)
* Recommended for indoor use only  

Drain Line Flow Controls

1" (22.5 mm)  ..............................................8-20 gpm (30-76 lpm)  

3/4" (1.9 cm)  ................................................4-7 gpm (15-29 lpm)

EQUIPMENT INSTALLATION

If you are also installing a water softener, the softener should 

be installed downstream of this system.

Grounding the Plumbing

It is important that the plumbing system be electrically 

grounded. When a water treatment system is installed a 

nonmetallic bypass valve may interrupt the grounding. To 

maintain continuity, a grounding strap can be purchased at a 

hardware store. When it is installed the strap will connect the 

plumbing into the system to the plumbing leaving the system.

Water Line and Bypass Connection

Once you have selected your location check the direction of the 

water flow in the main pipe.
A bypass valve system should be installed on all water 

conditioning systems. The bypass valve system isolates the 

filter from the water supply and provides untreated water to 

service during routine maintenance and servicing procedures.

B

1

3

2

Figure 3 

Normal Operation

•  Valves 1 and 3 open
•  Valve 2 closed

Bypassed Position

•  Valve 2 open
•  Valves 1 and 3 closed

The valve connects to the water system by means of a 

connector assembly. The connector is secured to the plumbing 

and then inserted into the universal ports on the valve. A clip is 

used to hold it in place.

Figure 4 Connector Assembly

Before inserting the connector:

•  Check that all O-rings are in place and not damaged.
•  O-rings are pre-lubricated. Sliding surfaces should be 

lubricated with 100% silicone grease.

Drain

Inlet

Outlet

4 • 

Autotrol

®

 363 Demand Automatic Filter Valve

Summary of Contents for AUTOTROL 363

Page 1: ...AUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual 2014 Pentair Residential Filtration LLC www pentairaqua com pro...

Page 2: ...ing seal Do not use pliers or pipe wrenches All plumbing must be completed according to local codes Soldering of the plumbing should be done before connecting to the valve Excessive heat will cause in...

Page 3: ...degrade to cause system failures Temperature Extreme hot or cold temperatures may cause damage to the valve or controller Freezing temperatures will freeze the water in the valve This will cause phys...

Page 4: ...softener should be installed downstream of this system Grounding the Plumbing It is important that the plumbing system be electrically grounded When a water treatment system is installed a nonmetallic...

Page 5: ...to 6 feet 1 8 m providing the run does not exceed 15 feet 4 6 m and water pressure at the filter is not less than 40 psi 2 76 bar Elevation can increase by 2 feet 61 cm for each additional 10 psi 69 b...

Page 6: ...media tank Turn on the water supply after five minutes Check for leaks The system is now fully operational INSTALLATION CHECKLIST ___ Read the owner s installation manual ___ Follow all safety guideli...

Page 7: ...set a time duration between cleaning cycles to ensure proper function of the filter in the event of a flow sensor malfunction press and hold and for three seconds The value in days between cleaning c...

Page 8: ...en and C 4 Repeat steps 2 and 3 to cycle through each position Quick Cycle to Service Position Simultaneously press and and hold for three seconds during any cleaning cycle step The control will skip...

Page 9: ...PT 360 Fltr 4002469 Kit DLFC 20GPM NPT 360 Fltr 4002476 Kit DLFC 4 0GPM BSP 360 Fltr 4002477 Kit DLFC 4 5GPM BSP 360 Fltr 4002478 Kit DLFC 5 0GPM BSP 360 Fltr 4002479 Kit DLFC 6 0GPM BSP 360 Fltr 4002...

Page 10: ...haft slots If motor continues to rotate indefinitely replace the following components in this order 1 Motor Assembly Optical Sensor 2 Control System Problem Possible Cause Solution Flowing or dripping...

Page 11: ...kwash Media Tank Inlet Outlet 1 4 3 2 BACKWASH Drain Drain Control FAST RINSE Untreated Water Rinse Media Tank Inlet Outlet 4 3 Drain Control 1 2 Drain Valve No 1 Closed 2 Open 3 Closed 4 Closed Valve...

Page 12: ...TA CHARTS 12 Autotrol 363 Demand Automatic Filter Valve 0 5 10 15 20 25 30 1 6 11 16 21 26 PRESSURE DROP IN PSI FLOW IN GPM Service Cv 5 43 0 5 10 15 20 25 30 35 1 6 11 16 21 PRESSURE DROP IN PSI FLOW...

Page 13: ...egistered marks of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal...

Reviews: