 460i and 460TC Control System Installation and Operation Instructions

Manual Regeneration

Electricity is used only to run the timer and to rotate 

the camshaft. All other functions are operated by water 

pressure. Therefore, in the event of a power outage, all the 

regeneration positions may be dialed manually by pressing 

the pointer knob with a straight-blade screwdriver and turning 

COUNTERCLOCKWISE.

•  Backwash...14 minutes
•  Brine and slow rinse...52 minutes
•  Brine refill...10 minutes
•  Fast rinse/refill...6 minutes

Do not exceed 10 minutes for the refill cycle as this will cause 

excessive salt usage during the next regeneration and possibly 

a salt residue in the conditioned water.
DO NOT advance the pointer knob directly to the conditioned 

water position (6 o’clock) when manually advancing the 

camshaft after a manual regeneration or when servicing the 

conditioner. Advance it to just past the fast rinse position, 

approximately 7 o’clock. The timer will then advance itself to 

the conditioned water position where the internal switch will 

turn the motor off. The internal switch will not be operated 

and the motor will continue to run if advanced directly to the 

conditioned water position.
If power fails during a conditioner regeneration, the cycle will 

be completed normally when the power is restored.

PROGRAMMING THE 460TC

Plug the wall-mount transformer into a functioning electrical 

outlet that is not controlled by a switch. Plug the transformer 

into the transformer plug receptacle on the control.
Open the access door by pushing the raised tab on the door 

toward the left while pulling the tab out (Figure 5).

460TC

DAYS

CLOCK

PM Indicator

Water Flow 

Indicator

Hour Time Display

Access Door

Raised 

Tab

Indicator 

Knob

Time Set Button

Transformer Plug 

Receptacle

Spare 

Jumper

Jumper

Timer 

Locking Pin

Figure 5  

Time of Day Setting

With the jumper on the set of pins next to the word 

TIME

 

(Figure 6), set the time of day to the closest hour by pressing 

the black 

TIME SET

 button. PM hours are indicated by a light 

next to the letters 

PM

 on the display window.

NOTE:   

The use of a small needle-nose pliers will aid in 

moving the jumper.

NOTE:   

The unit is factory set to regenerate at 2:00 a.m. If 

you prefer to have the unit regenerate at an earlier 

or later time, simply set the current time of day 

accordingly (e.g., to have the unit regenerate at 4:00 

a.m.—two hours later—set the clock two hours 

earlier than the actual time of day).

NOTE:   

The Timer Locking Pin should always be horizontal 

(Figure 5) during operation.

Days Setting

Move the jumper to the set of pins next to the word 

DAYS

 

(Figure 7). Press the black 

TIME SET

 button until the desired 

number of days between regeneration is displayed. The range 

is from 1 to 30 days.

TIME

DAYS

CLOCK

TIME

DAYS

CLOCK

TIME

DAYS

CLOCK

Figure 6   

Figure 7   

Figure 8   

Clock Setting

Move the jumper to the set of pins next to the word 

CLOCK

 

(Figure 8). Press the black

 TIME SET

 button until the desired 

clock setting is displayed. The clock range is 0 to 1. Select 0 

for the standard AM/PM clock or select 1 for a 24 hour clock.
Return the jumper to the top set of pins next to the word 

TIME

 

and replace the access door. The jumper must NOT be left 

on any pins other than the top pair next to the word 

TIME

Otherwise, the unit may show a blank display.

NOTE:   

A spare jumper is located on the bottom set of pins.

Memory Retention

During a power outage, all of the data in the microprocessor’s 

memory is stored in a special electronic chip called NOVRAM, 

Nonvolatile Random Access Memory. This data includes the 

time of day, water usage amounts, and the number of days 

since the last regeneration. The NOVRAM will maintain the 

data in its memory. When power is restored, the NOVRAM 

returns the data to the microprocessor and operation resumes 

as if an outage never occurred.
The time of day will be late by the length of the power 

outage. Most power outages are less than one minute in 

duration. Therefore, it may be months or years before the 

time display would require resetting. If an outage of one or 

more hours occurs, the time of day should be reset. No other 

reprogramming is necessary.

CONTROL FEATURES 460i 

CONTINUED

Summary of Contents for AUTOTROL 460i

Page 1: ... www pentairaqua com AUTOTROL 460i AND 460TC CONTROL SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS ...

Page 2: ...e by the length of the power outage Most power outages are less than one minute in duration Therefore it may be months or years before the time display would require resetting If an outage of one or more hours occurs the time of day should be reset No other reprogramming is necessary Self Adjusting Reserve Reserve refers to the amount of soft water that may be needed for the next 24 hours The micr...

Page 3: ...er million grains per gallon 17 1 Figure 2 Figure 3 Figure 4 Capacity Setting Move the upper jumper to the set of pins next to the word CAPACITY Figure 4 Press the black TIME SET Button until the correct capacity value is displayed The capacity range is 1 to 99 kilograins Refer to the salt setting chart Table 1 Return the jumper to the top set of pins next to the word TIME and replace the access d...

Page 4: ...k TIME SET button PM hours are indicated by a light next to the letters PM on the display window NOTE The use of a small needle nose pliers will aid in moving the jumper NOTE The unit is factory set to regenerate at 2 00 a m If you prefer to have the unit regenerate at an earlier or later time simply set the current time of day accordingly e g to have the unit regenerate at 4 00 a m two hours late...

Page 5: ...ever let the amount of salt in the brine tank be less than the amount required for the next regeneration Refer to the salt setting table Table 1 for proper salt settings To set the salt dial insert a screwdriver into the pointer knob Figure 9 and move the pointer to the proper setting NOTE To convert the salt settings from English to Metric divide by 2 2 Example 12 pound 5 5 kg of salt 2 2 Pointer...

Page 6: ...r and reset time of day display Defective circuit board Replace timer No water flow display when water is flowing Bypass valve in bypass Shift bypass valve to not in bypass position Meter probe disconnected or not fully connected to meter housing Fully insert probe into meter housing Restricted meter turbine rotation due to foreign matter in meter Remove meter housing free up turbine and flush wit...

Page 7: ...aking certain that correct salt dosage is used Fouled softener resin Use resin cleaner The use of resin cleaners in an unvented enclosure is not recommended Incorrect salt setting Set salt control to proper level See Salt Setting chart Incorrect hardness or capacity settings Set to correct values See Programming section Water hardness has increased Set hardness to new value See Programming section...

Page 8: ...ks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 1017948 REV G JL17 2017 Pentair Residential Filtration LLC All Rights Reserved For Autotrol Product Warranties visit Autotrol para las garantías de los productos vis...