10
•
Autotrol
®
Performa Valve with 400 Series Control water Conditioning Control System
SPECIFICAtIoNS
DAYS
CLOCK
Hydrostatic Test Pressure
300 psi (20.69 bar)
Working Pressure
20-125 psi (1.38 - 8.62 bar)
Standard Electrical Rating
115V 60 Hz
Optional Electrical Rating
115V 50 Hz, 230V 50 Hz, 200V 60Hz, 24V 60 Hz, 24V 50 Hz, 100V 60 Hz, 100V 50 Hz, 12V 50 Hz/
transformer, 12V 60 Hz/transformer
Electrical Cord (standard rating)
60-inch (1.5 m) 3-wire with plug
Pressure Tank Thread
2-1/2 inch-8 male
Riser Pipe Diameter Required
1.050 inch OD (26.7 mm)
Riser Pipe Length
1-1/8 ±1/8 inches (31.8 mm) higher than the top of mineral tank
Standard Connection
1-inch (25.4-mm) copper tube adapters
Optional Connections
3/4-inch, 22-mm, and 28-mm copper tube adapters 3/4-inch BSPT, 1-inch BSPT, 1-inch NPT
stainless steel pipe adapters 3/4-inch, 1-inch, 25-mm CPVC tube adapters
Brine Line Connection
3/8-inch NPT male
Drain Line Connection
3/4-inch NPT male
Optional Bypass Valve
Rotating handles, full 1-inch porting, reinforced plastic
Control Module, Tank Adapter
Reinforced plastic
Rubber Goods
Compounded for cold water service
Brine Refill Control
1 to 10 lbs (0.45 to 4.5 kg) of salt or 3 to 19 lbs (1.4 to 8.6 kg) of salt
Injector Size “A” White
Nozzle .042-inch (1.1 mm) diameter, Throat .089-inch (2.3 mm) diameter
Injector Size “B” Blue
Nozzle .052-inch (1.3 mm) diameter, Throat .099-inch (2.5 mm) diameter
Injector Size “C” Red
Nozzle .059-inch (1.5 mm) diameter, Throat .099-inch (2.5 mm) diameter
Injector Size "D" Green
Nozzle .071-inch (1.8 mm) diameter, Throat .147-inch (3.7 mm) diameter
Internal Backwash Controllers
7- through 14-inch (17.8 though 35.6 cm) diameter media tanks
All sizes to flow 4.5 gpm/sq ft (183 L/m/m2) of bed area.
For tank sizes above 14 inches in diameter, use an external flow control.