1.0 Mounting instructions
note
All AVID LP switchboxes are factory equipped with
direct and NAMUR mounting.
1.1 Please refer to the figures 1 and 2 below
to determine the type of mounting that is
required.
Figure 1 indicates the conventional direct
mount and figure 2 details the NAMUR
option.
1.2 Operate the actuator to the fully closed
position.
1.3 Direct mount
1.3a Before mounting the AVID LP it will be
necessary to remove the cover.
1.3b To do this, loosen the 4 off M5 captive
screws with either a 8 mm A/F spanner /
socket drive or an appropriately sized flat
blade screwdriver.
1.3c Remove the cover assembly by lifting
the cover vertically. Keep the cover safe
taking care not to damage the cover seal
detail.
© 2014 Pentair Ltd. All Rights Reserved.
Figure 1
Figure 2
Installation and operating instructions for AVID LP R2 with SPDT V3 Microswitches,
V3 Inductive Proximity Sensors or T-Switches.
AViD
LP R2
InstallatIon and operatIng InstructIons
www.pentair.com/valves
VcioM-02984-en 14/08
The following document details the installation,
operation and maintenance instructions for the
AVID LP R2 (low profile) giving 360° visual and
electrical valve position.
1.4 nAMur Mount
note
Due to the mounting hole pattern of the AVID LP
housing being 93.5 x 41.3 mm equal about the center
of the shaft, a modified Namur bracket is required.
The modification can either be 4 off M5 tapped holes
or 4 off M5 clearance holes.
1.4a Secure the appropriately sized modified
Namur bracket to the actuator using
the screws / washers supplied with the
Namur kit finger tight only.
1.4b(1) For mounting brackets with 4 off M5
tapped holes, mount the LP switchbox
to the mounting bracket by engaging
the Namur shaft drive into the actuator
Namur pinion slot.
1.3d Mount the AVID LP switchbox to the
actuator by aligning the 11 x 16 mm shaft
adaptor to the actuator pinion coupler.
1.3e Ensure that the base of the AVID LP
housing sits flush with the top of the
actuator.
1.3f Locate and tighten the 4 off M5 captive
screws in the base of the housing with
either a 8 mm A/F socket drive or an
appropriately sized flat blade screwdriver.
1.3g Tighten the screws to a torque value of
18 to 22 Lb/Ins.
AVID coupler 11 x 16 mm
Actuator namur slot
Namur
shaft drive
Bracket – customer supply
1.4b(2) Locate and tighten the 4 off M5 captive
screws in the base of the housing with
either a 8 mm A/F spanner / socket
drive or an appropriately sized flat blade
screwdriver.
1.4b(3) Tighten the screws to a torque value
of 18 to 22 Lb/Ins.
1.4c(1) For mounting brackets that have 4 off
M5 clearance holes it will be necessary
to replace the 4 off M5 captive
LP housing mounting screws with
M5 x 16 mm screws to be sealed with
new sealing caps.
1.4c(2) Tighten the screws to a torque value
of 18 to 22 Lb/Ins.