COLORCASCADE
®
Color Pool and Spa Light Installation and User’s Guide
COLORCASCADE
®
Color Pool and Spa Light Installation and User’s Guide
CONNECTING COLORCASCADE
®
LIGHTS
TO THE AUTOMATION CONTROL SYSTEM
1.
Load Center:
Unlatch the enclosure door spring latch, and open the door.
2.
Discharge Electrostatic energy before removing the cover by first
touching the metal part of the enclosure.
3. Loosen the two (2) retaining screws from the HIGH VOLTAGE FRONT
PANEL. Remove the panel from the enclosure.
4. Connect the 120 Volt side of a 12 VAC transformer to the LOAD SIDE of
one of the auxiliary (AUX) relays in the load center.
5. Connect the Neutral conductor from the 12 VAC transformer to the Neutral
bus bar in the load center.
6. After the connection has been completed, close the control panel and
secure it with the two (2) retaining screws.
7. Close the load center front door. Fasten the spring latch.
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect AC power to EasyTouch
®
and IntelliTouch
®
Control System load
center at the circuit breaker before servicing, or removing the
HIGH VOLTAGE
FRONT PANEL
. Failure to do so could result in death or serious injury to installer,
service person, pool users, or others due to electrical shock.
12