background image

English

X

0

18

36

54

72

90

108

0

2

4

6

8

10

12

0

10

20

30

40

50

60

0

51

102

152

203

254

305

100W

200W

400W

800W

1300W

WIRING

Reference Wiring Illustration on page 6

1.  All wiring must comply with applicable local codes and ordinances.

2.  Connect the heater lead wires to the proper A.C. power source. Power source for 800 

and 1300 watt heaters should be continuous.

3.  The heater must be properly grounded.

NOTE: Exposed wires should not come in contact with the heater housing.

SETTING THE THERMOSTAT

1.  The heater is controlled by an adjustable thermostat. Set the thermostat to the desired 

temperature. It is recommended not to exceed 75 F for most applications.

MAINTENANCE

1.  Always disconnect power supply before inspecting or working on the heater.

2.  Generally the unit requires no maintenance since the fan bearings are permanently 

lubricated and sealed.

Temperature Rise vs. Distance Above Heater

Distance Above Heater (mm)

(Minimum 

recommended distance 

above heater)

Distance Above Heater (in.)

Temper

atur

e R

ise A

bo

ve Hea

ter (°F)

Temper

atur

e R

ise A

bo

ve Hea

ter (°C

)

© 2012 Pentair Technical Products

- 4 -

PH 763 422 2211  •  hoffmanonline.com

87565511

Summary of Contents for DAH1001A

Page 1: ...Electric Heaters 2012 Pentair Technical Products PH 763 422 2211 hoffmanonline com 87565511 Rev D P N 28359001 ...

Page 2: ...ls 2 If continuous operation of the heater is essential to the safe functioning of any other equipment adequate warning devices must be installed to assure safe operation at all times Do not use these electric heaters in dusty dirty corrosive or hazardous locations Reduce the thermostat from factory setting to a recommended setting not to exceed 75 F for most applications Portions of the heater ca...

Page 3: ...d the air outlet openings at the top as shown 4 The recommended clearances shown by the shadowed area indicates the space that should be kept free of components for safe operation of the heater WARNING Heat sensitive components must not be placed above the heater discharge area 5 Four 10 32 UNF self tapping screws are included for installation Vertical Surface Mounting Optional Horizontal Surface ...

Page 4: ...r housing SETTING THE THERMOSTAT 1 The heater is controlled by an adjustable thermostat Set the thermostat to the desired temperature It is recommended not to exceed 75 F for most applications MAINTENANCE 1 Always disconnect power supply before inspecting or working on the heater 2 Generally the unit requires no maintenance since the fan bearings are permanently lubricated and sealed Temperature R...

Page 5: ...English L1 N or L2 M T 100 800 Watt Schematic M L S L1 T N or L2 1300 Watt Schematic 2012 Pentair Technical Products 5 PH 763 422 2211 hoffmanonline com 87565511 ...

Page 6: ...Wiring Illustration 1 3 2 1 2 3 2012 Pentair Technical Products 6 PH 763 422 2211 hoffmanonline com 87565511 ...

Page 7: ...Notes 2012 Pentair Technical Products 7 PH 763 422 2211 hoffmanonline com 87565511 ...

Page 8: ...Notes 2012 Pentair Technical Products 8 PH 763 422 2211 hoffmanonline com 87565511 ...