background image

Rev. D

    2-19-04

1

P/N

   

520041

EZ100 EASYTOUCH

 

OWNER’S MANUAL

4-Function Hand-Held Wireless Remote Control

Important  Notice

Attention  Installer.

This manual contains important information about the installation, operation and safe use of this

product. This information should be given to the owner/operator of this equipment.

Before installing this product, read and follow all warning notices and instructions which are included. Failure to

follow safety warnings and instructions can result in severe injury, death, or property damage.

Call (800) 831-7133 for additional free copies of these instructions.

WARNING

IMPORTANT  SAFETY  INSTRUCTIONS

READ  AND  FOLLOW  ALL  INSTRUCTIONS

SAVE  THESE  INSTRUCTIONS

Pentair Pool Products

1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400

IMPORTANT

The Hand-held remote may be used with wet hands, but should never be submersed in water, as this could

damage the unit. If accidental submersion occurs, dry unit out by removing battery cover and removing battery.

Position unit so that water can drain out. Reassemble when completely dry.

Table of Contents

SECTION I.

APPLICATION ............................................................................................................................................... 2

SECTION II.

KIT INCLUSION ............................................................................................................................................ 2

SECTION III.

RECEIVER ....................................................................................................................................................... 2

SECTION IV.

POWER CENTER ........................................................................................................................................... 3

SECTION V.

POWER ISOLATION CIRCUIT BOARD .................................................................................................... 3

SECTION VI.

CABLE SPLITTERS (OPTIONAL) .............................................................................................................. 3

SECTION VII. HAND-HELD REMOTE ................................................................................................................................ 3
SECTION VIII. USING THE HAND-HELD REMOTE .......................................................................................................... 3
SECTION IX.

RECEIVER CIRCUIT BOARD ...................................................................................................................... 4

SECTION X.

AUTOMATIC COUNTDOWN CYCLE (OPTIONAL) ............................................................................... 5

SECTION XI.

CUSTOMIZING THE COMMUNICATION LINK ..................................................................................... 6

SECTION XII. TRANSMITTER BATTERY REPLACEMENT ........................................................................................... 6
SECTION XIII. TROUBLESHOOTING ................................................................................................................................... 7

Summary of Contents for EASYTOUCH EZ100

Page 1: ...Pentair Pool Products 1620HawkinsAve Sanford NC27330 919 774 4151 10951WestLosAngelesAve Moorpark CA93021 805 523 2400 IMPORTANT The Hand held remote may be used with wet hands but should never be submersed in water as this could damage the unit If accidental submersion occurs dry unit out by removing battery cover and removing battery Position unit so that water can drain out Reassemble when comp...

Page 2: ... of 8 to 10 feet away from any air blower which may be part of the equipment set The Receiver will not operate properly if it is close to a blower which is operating InordertomounttheReceiver itwillbenecessarytoremovethetworetainingscrewslocatedontheundersideof theReceiver andcarefullyslidetheReceivercaseupandoffofitsbackplate Temporarilypositionthebackplate againstitsmountingsurfacesothattheRecei...

Page 3: ...fromSocket 2marked CP100 IfthereisnoIndoorRemote thesilvercableforthereceivermaybe pluggeddirectlyintoSocket 1ofthePowerCentercircuitboard IftheControlSystemincorporatesanIndoor Remote itwillbenecessarytouseaCableSplitterforSocket 1 SeeSECTIONVI CABLESPLITTERS Optional SECTIONVI CABLESPLITTERS Optional IftheControlSystemincorporatesanIndoorRemote disconnectanyexistingIndoorRemotecablesfromSocket 1...

Page 4: ...A4 positionconfigurationswitch designatedS2 whichcanbeusedtoconfigureanautomaticcountdown cyclefortheSpaand orAux1circuit 2 A10 positionconfigurationswitch designatedS1 whichcanbeusedtocustomizethecommunicationlink betweentheReceiverandHand heldRemote 3 2 qty statuslights designatedPOWERandCOMMAND whichareusedfortrouble shooting POWER IndicatesthattheControlSystemissupplyingpowertotheReceiverunit ...

Page 5: ...sedtosetacountdowncycle time outfeature fortheSpaand orAux1circuit Oncethisfeaturehas beenenabled theequipmentwillautomaticallyturnoffafterthecountdowncycleirrespectiveofhowthecircuit wasturnedon byIndoorRemote Spa sideRemoteorHand heldRemote UseapapercliporotherbluntinstrumenttoslidetheappropriateswitchatS2tothe ON or OFF position inaccordancewiththefollowingpictorial ...

Page 6: ... heldRemote thecommunicationlinkwillnotfunction Labelshavebeenprovided markedwiththemostcommonlyusedfunctions Theselabelsmaybeaffixedtothe sideoftheHand heldRemotetoassistwithbuttonidentification Receiver Transmitter S1 Switch COMMUNICATION LINK ADJUSTMENT NOTE All Program Switches are Factory set to ON Matching Code Example Remote switches 2 4 6 ON Receiver switched 2 4 6 ON Affix Button ID Label...

Page 7: ...e Receiver board incorrect circuit Unit fails to operate or fails to Undue electrical noise Relocate the Receiver away from operate dependably at range equipment such as blower motors Too many obstructions between the Relocate the Receiver in a location that Transmitter and Receiver provides fewer obstructions to the area the user commonly operates the Transmitter Receiver unit is too near the gro...

Page 8: ...P N 520041 8 Rev D 2 19 04 Pentair Pool Products 1620HawkinsAve Sanford NC27330 919 774 4151 10951WestLosAngelesAve Moorpark CA93021 805 523 2400 SAVE THESE INSTRUCTIONS ...

Reviews: