Installer manual Evolio 255 740-760 - Programming
44 / 90
Ref. MKT-IM-037 / D - 25.10.2021
Salt setting
Evolio 255 10
Evolio 255 15
Evolio 255 20
Evolio 255 30
L
45.0
46.7
55.0
53.3
S
91.0
133.3
160.0
136.7
H
180.0
226.7
250.0
226.7
1. Press
.
ð
Setting flashes.
2. Adjust displayed settings with
and
.
3. Press
to validate the selection and advance to the
next parameter using
or
.
5.4.7
Estimated capacity
Info
The system capacity is displayed in kilograms equivalent CaCO
3
of hardness removed
before a regeneration is necessary when programmed in metric units mode.
Value is derived from the system’s resin volume input and salt amount input and must
be fine tuned for optimal operation.
Set the estimated capacity, in kg as CaCO
3
, following the following table.
Salt setting
Evolio 255 10
Evolio 255 15
Evolio 255 20
Evolio 255 30
L
0.3
0.5
0.7
1.0
S
0.5
0.9
1.4
1.9
H
0.7
1.2
1.6
2.3
1. Press
.
ð
The amount number flashes.
2. Adjust displayed capacity with
and
.
3. Press
to validate the selection and advance to the
next parameter using
or
.
5.4.8
Hardness
Set water hardness to treat at installation site in mg/L as CaCO3. Program the value of inlet
hardness taken away from expected residual hardness. For example, if inlet hardness is 300 mg/L
as CaCO
3
and residual hardness is set to 100 mg/L as CaCO
3
, set 300-100=200 mg/L as CaCO
3
.
Summary of Contents for Evolio 255 10
Page 1: ...www pentairaquaeurope com INSTALLER MANUAL EVOLIO 255 740 760 RESIDENTIAL ...
Page 64: ...Installer manual Evolio 255 740 760 Maintenance 64 90 Ref MKT IM 037 D 25 10 2021 ...
Page 72: ...Installer manual Evolio 255 740 760 Maintenance 72 90 Ref MKT IM 037 D 25 10 2021 ...
Page 74: ...Installer manual Evolio 255 740 760 Maintenance 74 90 Ref MKT IM 037 D 25 10 2021 ...
Page 78: ...Installer manual Evolio 255 740 760 Maintenance 78 90 Ref MKT IM 037 D 25 10 2021 ...