Installer manual Evolio 255 740-760 - Programming
46 / 90
Ref. MKT-IM-037 / D - 25.10.2021
ð
A small “C#” with a number will be displayed indicating the controller is in cycle time
programming.
ð
The number indicates the cycle being viewed or changed.
C1-Backwash
C5-Fast Rinse
C2*-Brine Draw
C6-2nd Backwash
C3*-Slow Rinse
C7-2nd Fast Rinse
C4-Re-pressurize
C8*-Refill
* The cycles time are pre-selected by the software based upon the programmed volume of resin
and salt dosage. Cycle time are not modifiable. During the regeneration, the controller will display
C2 for the entire duration of C2+C3. The effective difference between brine draw and slow rinse
will be hydraulically done when the valve air-check's closes once all the brine have been drawn.
Info
See System service and regeneration cycles (7 cycles operation) [
Page 17] for more
information about cycles.
Cycle
Salt
setting
Evolio 255 10
Evolio 255 15
Evolio 255 20
Evolio 255 30
C1
L
8 min
8 min
14 min
14 min
S
H
C2
L
4.7 min
5.2 min
6.3 min
7.3 min
S
9.4 min
15.5 min
17.6 min
18.9 min
H
18.9 min
25.8 min
27.7 min
31.5 min
C3
L
11.7 min
17 min
18.7 min
17.8 min
S
33.9 min
49.3 min
54.2 min
51.7 min
H
33.9 min
49.3 min
54.2 min
51.7 min
C2 + C3
L
17 min
22 min
25 min
25 min
S
44 min
65 min
72 min
71 min
H
53 min
75 min
82 min
83 min
C4
L
3 min
3 min
3 min
3 min
S
H
C5
L
3 min
3 min
6 min
6 min
S
H
C6
L
1 min
1 min
1 min
1 min
S
H
Summary of Contents for Evolio 255 10
Page 1: ...www pentairaquaeurope com INSTALLER MANUAL EVOLIO 255 740 760 RESIDENTIAL ...
Page 64: ...Installer manual Evolio 255 740 760 Maintenance 64 90 Ref MKT IM 037 D 25 10 2021 ...
Page 72: ...Installer manual Evolio 255 740 760 Maintenance 72 90 Ref MKT IM 037 D 25 10 2021 ...
Page 74: ...Installer manual Evolio 255 740 760 Maintenance 74 90 Ref MKT IM 037 D 25 10 2021 ...
Page 78: ...Installer manual Evolio 255 740 760 Maintenance 78 90 Ref MKT IM 037 D 25 10 2021 ...