Installer manual Evolio 255 740-760 - Programming
Ref. MKT-IM-037 / D - 25.10.2021
43 / 90
5.4.3
Day of week
Set the current day of the week.
1. Press
.
ð
Arrow flashes.
2. Select displayed day with
and
.
3. Press
to validate the selection and advance to the
next parameter using
or
.
5.4.4
Regeneration time
Set the time at which regeneration will take place.
1. Press
.
ð
Regeneration time flashes.
2. Adjust displayed time with
and
.
3. Default setting: 2:00am.
4. Press
to validate the selection and advance to the
next parameter using
or
.
5.4.5
Calendar override
Set number of days for calendar override.
1. Press
.
ð
Number of days flashes.
2. Adjust displayed number with
and
.
ð
Default setting for calendar override: 0 =
deactivated.
ð
Days can be adjusted from 0.5 (twice a day) to 99
days.
3. Press
to validate the selection and advance to the
next parameter using
or
.
5.4.6
Salt setting
Set the salt amount used for each regeneration. Three options are available:
• L - low;
• S - standard;
• H - high.
Refer to the following table to define the amount of salt, in g/L of resin, for your softener.
Summary of Contents for Evolio 255 10
Page 1: ...www pentairaquaeurope com INSTALLER MANUAL EVOLIO 255 740 760 RESIDENTIAL ...
Page 64: ...Installer manual Evolio 255 740 760 Maintenance 64 90 Ref MKT IM 037 D 25 10 2021 ...
Page 72: ...Installer manual Evolio 255 740 760 Maintenance 72 90 Ref MKT IM 037 D 25 10 2021 ...
Page 74: ...Installer manual Evolio 255 740 760 Maintenance 74 90 Ref MKT IM 037 D 25 10 2021 ...
Page 78: ...Installer manual Evolio 255 740 760 Maintenance 78 90 Ref MKT IM 037 D 25 10 2021 ...