body.
Figure 9
12. To restuff a valve body, first take the end ring (the plastic
or brass ring without holes), then with your thumb press
the button on the brass sleeve end. The large dia. inner
portion is now exposed (see Figure 8). Place the end ring
on this pilot with the lip on the end ring facing the tool.
Push the tool into the valve body bore until it bottoms.
While the tool is in the valve body, take a seal and press it
into the inside diameter of the exposed brass female end.
13. Remove the tool, turn it end for end and insert it into
the valve body bore. While holding the large dia. of the
tool, slide it all the way into the valve body bore until it
bottoms. Then push the center button to push the seal of
the tool and leave it in place in the valve body.
14. Remove the tool from the valve body and push the center
on the brass female end to expose the pilot on the
opposite end. Place a spacer on this end and insert the
spacer and tool into the valve.
GENERAL SERVICE HINTS FOR METER
CONTROL
Problem: Softener delivers hard water
Reason:
Reserve capacity has been exceeded.
Correction:
Check salt dosage requirements and reset
program wheel to provide additional reserve.
Reason:
Program wheel is not rotating with meter output.
Correction:
Pull cable out of meter cover and rotate
manually. Program wheel must move without binding and
clutch must give positive clicks when program wheel strikes
regeneration stop. If it does not, replace timer.
Reason:
Meter is not measuring flow.
Correction:
Check meter with meter checker.
SEAL & SPACER TOOLS & REPLACEMENT
CONTINUED
Summary of Contents for Fleck 2850s
Page 1: ...waterpurification pentair com FLECK 2850S SERVICE MANUAL...
Page 7: ...FLECK 2850S Service Manual 7 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 8: ...8 FLECK 2850S Service Manual 37 615023200 Rev A 3200 TIME CLOCK TIMER ASSEMBLY 36 38...
Page 10: ...10 FLECK 2850S Service Manual 3210 METER DELAYED TIMER ASSEMBLY 41 42 61502 3210 Rev A 40 43...
Page 21: ...FLECK 2850S Service Manual 21 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 26: ...26 FLECK 2850S Service Manual 1700 BRINE SYSTEM ASSEMBLY 60034 Rev D 28 29...
Page 34: ...34 FLECK 2850S Service Manual 2310 SAFETY BRINE VALVE...
Page 37: ...FLECK 2850S Service Manual 37 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 41: ...FLECK 2850S Service Manual 41 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 44: ...44 FLECK 2850S Service Manual DIMENSIONAL DRAWING...
Page 55: ...FLECK 2850S Service Manual 55...