Installer manual Fleck 5600 SXT - Programming
Ref. MKT-IM-013 / E - 23.09.2020
57 / 104
Parameter
Options
Definition
Note
RC
Fixed reserve
capacity
0 to 50
%
Only displayed for volumetric
regenerations and if set in reserve
selection.
DO
Days override
0 to 99
Day
-
RT
Regeneration
time
00:00:00 to
23:59:59
Hour
Regeneration time will not appear
unless regeneration day override is
on.
B1
First backwash
0 to 199
Minute
Only displayed for dF2b regeneration
flow. In case of dF1b regeneration
flow, the screen shows BW.
BD
Brine draw
BD consist of time for brine draw and
slow rinse.
B2
Second
backwash
Only shown in dF2b regeneration flow.
RR
Rapid rinse
-
BF
Brine fill
0 to 199
Minute
-
BW
Backwash
-
Rn
Cycle number
n=1 to 6
Only if "Othr" is chosen under
VT
. R1,
R2, R3, etc... will be displayed instead.
Dn
Day of week,
n=1 to 7
ON - OFF
-
Regeneration setting for each day of
the week. OFF by default.
Not available for 9000 serie valves.
CD
Current day
1 to 7
Day of the week
Not available for 9000 serie valves
FM
Flow meter type
P0.7
¾" paddle wheel -
t0.7
¾" turbine
-
P1.0
1" paddle wheel
-
t1.0
1" turbine
-
P1.5
1½" paddle wheel -
t1.5
1½" turbine
-
P2.0
2" paddle wheel
-
Gen
Generic or
non-Fleck
-
K
Meter pulse
0.1 to 999.9
Litre
Only displayed for generic flow meter
type.