Installer manual Fleck 5600 SXT - Maintenance
Ref. MKT-IM-013 / E - 23.09.2020
85 / 104
9.4.8
BLFC cleaning
1. Using a wrench, remove the BLFC holder (
1
).
2. Using pliers, remove the cage (
4
) form the BLCF holder (
1
).
3. Remove the BLFC washer (
3
) from the BLFC holder (
1
).
4. Clean the BLFC washer (
3
) with a terry cloth.
5. Clean the cage (
4
).
6. Lubricate the seal (
2
) with approved lubricant only.
Caution - material
Risk of damage due to wrong lubricant use !
Do not use petroleum-based lubricants such as vaseline, oils, or hydrocarbon-based
lubricants.
Use only approved silicone grease or soapy water !
7. Reverse above procedure steps to rebuild.
Mandatory
The washers (
3
) have to be installed with their chamfered side upfront the water
stream flow.
Flow indication must be visible after the washer (
3
) is placed on the holder (
1
).