Installer Manual Fleck 5812 - XTR - Troubleshooting
118 / 132
Ref. MKT-IM-019 / E - 14.10.2019
10.
Troubleshooting
Problem
Cause
Solution
Water softener
fails to regenerate
automatically.
Cord plugged into intermittent or
switched off power source.
Connect to constant power source.
Disconnected/faulty meter cable.
Reconnect/replace cable.
Defective power cord.
Replace cord.
Defective controller, meter or sensor. Replace or repair.
Bad programming.
Program correctly.
Regeneration at
wrong time.
Controller improperly set, due to
power failure.
Reset controller.
Loss of capacity.
Increased raw water hardness.
Reset unit to the new hardness.
Brine concentration and/or quantity.
Keep brine tank full of salt at all times.
Clean it yearly. Salt may be bridged. If
using a salt grid plate ensure refill
water is over it.
Resin fouling.
Call dealer, find out how to confirm it,
clean the resin and prevent future
fouling.
Poor distribution, Channeling (uneven
bed surface).
Call dealer. Check distributors and
backwash flow.
Internal valve leak.
Call dealer. Replace spacers, seals
and/or piston.
Resin age.
Call dealer. Check for resin oxidation
caused by Chlorine. Mushy resin.
Resin Loss.
Call dealer. Check for correct bed
depth. Broken distributors.
Poor water quality.
Check items listed in loss of capacity.
Bypass valve open.
Close by-pass valve.
Channeling.
Check for too slow or high service flow.
Check for media fouling.
Mixing wrongly set.
Set mixing correctly.
Summary of Contents for FLECK 5812 XTR
Page 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Page 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Page 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Page 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Page 132: ...www pentairaquaeurope com...