Installer Manual Fleck 5812 - XTR - System sizing
Ref. MKT-IM-019 / E - 14.10.2019
35 / 132
To calculate the system mass capacity:
To calculate the system combined capacity:
To calculate the system volume capacity:
Caution
If a mixing device is set on the valve before meter, TH = TH
inlet
- TH
outlet
.
Having determined the previous capacity allows the operator to know the service cycle duration.
170
58.5
5.85
3.27
200
62.7
6.27
3.5
230
66.9
6.69
3.74
260
71
7.1
3.97
290
75.3
7.53
4.21
M
capacity
= V
resin
x C
resin ex
with:
M
capacity
: system mass capacity [g as CaCO
3
]
V
resin
: volume of resin [L]
C
resin ex
: resin exchange capacity [g/L
resin
as CaCO
3
]
C
capacity
= V
resin
x C
cor resin ex
with:
C
capacity
: system combined capacity [°f.m
3
or °dH.m
3
]
V
resin
: volume of resin [L]
C
cor resin ex
: corresponding resin exchange capacity
[°f.m
3
/l or °dH.m
3
/l]
V
capacity
= M
capacity
/ TH
inlet
or
V
capacity
= C
capacity
/ TH
inlet
with:
V
capacity
: system volume capacity [m
3
]
M
capacity
: system mass capacity [g as CaCO
3
]
C
capacity
: system combined capacity [°f.m
3
or °dH.m
3
]
TH
inlet
: inlet water hardness [mg/L as CaCO
3
or °f or °dH]
Salt amount
[g/L
resin]
Corresponding resin exchange
capacity in [g/L
resin
] as CaCO
3
°f.m
3
[per L
resin
]
°dH.m
3
[per L
resin
]
Summary of Contents for FLECK 5812 XTR
Page 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Page 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Page 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Page 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Page 132: ...www pentairaquaeurope com...